Black Box LMC543C Скачать руководство пользователя страница 19

 

38

 

Configuring for EXT MGMT 

By adding a connection to the EXT MGMT port and configuring the Managed Media 
Converter, you can continue the management path past the module. 

To configure this mode, perform the following: 

1.

 

Set the management DIP switch ON for the ports using management (in this example it is 

the OPTICS (or UPLINK) 3 = ON and EXT MGMT 1 = ON). 

2.

 

Set Transparent Mode to allow both tagged and untagged traffic to pass: 

a.

 

From the Main Configuration Screen, press the space bar and type 

config

.  The 

Configuration Screen displays: 

 

b.

 

Enter 

Y

 in the Transparent Mode field and press any key (except S or Q) to open the 

Transparent Mode Setup screen. 

 

c.

 

Press 

S

 or 

F3

 to save without setting any transparent mode options.  This will set all 

untagged traffic as management (

Is a VLAN tag required on Management 

packets? [ N ]

)

.

 

d.

 

Type 

reboot

                  TRANSPARENT MODE SETUP 
Is a VLAN tag required on Management packets? [ N ] 
 
Do you want to enter the Extra Tag mode? Enter Y for Extra Tagging. 
Enter N if you do not want Extra Tags [ N ] 
 
Are VLAN Tags required on the EXT Port?       [ N ] 
 
Type S or F3 to save the new information 
Type Q of F4 to quit and cancel changes 
 
Reboot is required for any change to take affect. 

Transparent Mode – with either (not both) Data and Optics Mgmt dipswitches
set to on, all traffic passes between Optics and Data port EXCEPT what has 
been defined as the Management Domain. The Management Domain can either be 
defined as untagged traffic or traffic with a specified VLAN ID. 
 
In Transparent Mode with BOTH Optics and Data Mgmt dipswitches set to off, 
all traffic passes between the Optics and Data Ports. 
 
Default Mode – the unit passes only Untagged Packets. 
 
The unit is currently 

in Default Mode

 
Enter Y for Transparent Mode, N for no Transparent Mode or <enter> to  
move to other options [ Y ] 

 

15

 

When FiberAlert is enabled on the remote module (preferred use), a fault on the receive side 
of the OPTICS (or UPLINK) port causes the transmitter side to turn off.  This allows the fiber 
connected device to detect a fault in its transmission fiber. 

FiberAlert

Single fiber fault with FiberAlert enabled on remote

X

X

X

X

X

X

CONNECTED

DEVICE

CONNECTED

DEVICE

HOST

REMOTE

 

WARNING 

Do not enable FiberAlert on both modules when using Managed Media Converter in 
pairs.  This will cause them to lock up when a fault occurs on the fiber.  Only enable 
FiberAlert on the remote module. 

Using LinkLoss and FiberAlert 

In a typical central site to remote site media conversion, it is recommended that you enable 
the LinkLoss and FiberAlert features as indicated in the table.   

FiberAlert and LinkLoss 

Feature 

Enabled 

Fault Location 

Port affected 

FiberAlert 

Remote Side Only 

Fiber 

Fiber 

TX LinkLoss 

Remote Side (or both) 

Twisted Pair

 

Fiber 

FX LinkLoss 

Host Side (or both) 

Fiber 

Twisted Pair 

Содержание LMC543C

Страница 1: ...tside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site w...

Страница 2: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenn...

Страница 3: ...nnection 2 Management Software 2 About Dynamic Host Control Protocol DHCP 3 About Features and Configuration 4 Hardware Configuration 4 Installation Instructions 6 Assigning IP Information 7 Software...

Страница 4: ...0 km Requires SFP I55 Extended Diagnostic Module NOTE Single strand versions SS display the transmit frequency in the Media 2 column 53 Safety Certifications UL CUL Listed to Safety of Information Tec...

Страница 5: ...g with EtherType TPID selection Remote monitoring and automatic alarms Bandwidth limiting The Host Remote pair configuration provides the following features Extends any 10 100 Mbps Ethernet based VLAN...

Страница 6: ...t and is accessed by using the included RJ 45 to DB 9 adapter The serial connection provides access the Managed Media Converter module configuration screens these configuration screens are also access...

Страница 7: ...nits in Host Remote applications and then reconfiguring all of the settings 3 iConfig Utility iConfig is a configuration utility in iView that lets you quickly and easily complete the first stages of...

Страница 8: ...must be selected using DIP switches These feature selections include the following Enable Disable management on each port DIP switches 1 2 and 3 Configure the module to be either a Standalone a Host o...

Страница 9: ...traffic passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID I...

Страница 10: ...ve screw The Managed Media Converter module includes on board SNMP logic When installed in an iMediaChassis manage the Managed Media Converter module from the chassis by using the Unified Management A...

Страница 11: ...tall a 100 Mbps speed SFP Many SFPs including those from Black Box feature enhanced diagnostics capabilities with a Digital Diagnostics Monitoring Interface DDMI DDMI statistics provide real time acce...

Страница 12: ...UPLINK port except for the device s management traffic When in Loopback mode the Managed Media Converter module stops the OPTICS or UPLINK port traffic from continuing on out of the DATA port Address...

Страница 13: ...0 VLAN 32 0 0 VLAN 11 0 0 VLAN 22 0 0 Valid Vlan IDs are between 1 and 4094 Valid priorities are between 0 and 7 Type S or F3 to save the changes Type Q or F4 to quit and cancel changes Transparent Mo...

Страница 14: ...lect the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 5 On the Host Managed Media Converter module enter Y in the Are Extra Tags left on the Data Port field to only accept the Ext...

Страница 15: ...ort N Select the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter the Extra Tag mode Enter Y...

Страница 16: ...N ID 7 as management g Type reboot Now the Managed Media Converter is configured to pass all data between the OPTICS or UPLINK and DATA ports except that which is tagged with VLAN ID 7 All data tagged...

Страница 17: ...Tag is 7 Management Priority is 0 e Make sure the Are VLAN Tags required on the EXT Port field is set to N TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter th...

Страница 18: ...TE 39 Now the Managed Media Converter is configured to pass only tagged data between the OPTICS or UPLINK and DATA ports All untagged data is considered management traffic and passes from the OPTICS o...

Страница 19: ...passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID In Transpa...

Страница 20: ...air 2 TX LinkLoss detects the fault and disables the OPTICS or UPLINK port 3 FX LinkLoss detects the fiber loss and disables the DATA port The link fault is passed through the media conversion and is...

Страница 21: ...can also be performed using a Telnet session You can only use one Telnet session at a time There are three levels of Telnet account access User View status change own password and reboot Operator User...

Страница 22: ...connected device Press Enter after each You can also assign a default gateway to allow the unit to be visible beyond the local network press Enter to skip When finished press Enter then type reboot f...

Страница 23: ...e a new community string go to the main configuration screen and press C Enter the name of the new community up to 16 characters no spaces and press Enter Then type one of the following to assign the...

Страница 24: ...you can launch a console session through the serial port and type in the command cleandb If both the serial and the iConfig passwords are forgotten you must contact technical support Ending Your Sess...

Страница 25: ...two levels of cleandb The first level resets the Telnet iConfig password and all of the SNMP database values The second level additionally resets the IP address IP Subnet Gateway VLAN settings CLI com...

Страница 26: ...FXLinkLoss Only Enabled TXLinkLoss Only Enabled FiberAlert Plus FXLinkLoss Enabled FiberAlert Plus TXLinkLoss Enabled TXLinkLoss Plus FXLinkLoss Enabled TXLinkLoss FXLinkLoss FiberAlert Enabled Fiber...

Страница 27: ...trol Settings Unit FlowControl Disable FlowControl Globally Unit FiberAlert TXLinkLoss Plus FXLinkLoss Enabled Unit LoopBack No LoopBack Normal Traffic Mode Unit Max FrameSz Oversized Frames 1536 802...

Страница 28: ...management isolation and is not recommended for normal use This section describes the telnet serial port screens and fields available for configuring the Managed Media Converter modes 29 In the above...

Страница 29: ...0 0 VLAN 25 0 0 VLAN 4 0 0 VLAN 15 0 0 VLAN 26 0 0 VLAN 5 0 0 VLAN 16 0 0 VLAN 27 0 0 VLAN 6 0 0 VLAN 17 0 0 VLAN 28 0 0 VLAN 7 0 0 VLAN 18 0 0 VLAN 29 0 0 VLAN 8 0 0 VLAN 19 0 0 VLAN 30 0 0 VLAN 9 0...

Страница 30: ...a Tagging Enter N if you do not want Extra Tags N Are VLAN Tags required on the EXT Port N Type S or F3 to save the new information Type Q of F4 to quit and cancel changes Reboot is required for any c...

Отзывы: