Setting the System's Real-Time Clock
To change the system clock time, position the
>
cursor at the "
Set Clock
" field. The message
'
Enter time and date (hh-mm-ss dd/mm/yy)
' will appear at the bottom of the screen. The
time should be entered following the format shown. Time updates may be entered without a
date, but to change the date, both must be entered.
Viewing the Statistics pages
The Statistics pages give regularly updated information as to the performance of the E1 data
link(s).
It is important to note that there are in fact
four
statistics pages available for viewing:
m)
Local Main Link
n)
Local D&I Link (if fitted)
o)
Remote Main Link
p)
Remote D&I Link (if fitted)
These pages are accessed by moving the cursor to the 'Statistics :' field, using the
spacebar
to
select either the main link or the D&I link (if fitted). The local and remote pages are
accessed in the normal manner (using the spacebar on the 'Configuration' field).
2 MEGABIT E1 MULTIPLEXER V1.01
=============================== 09:45 25/11/96 ==================================
Main Link (EUR) : SYNCHRONISED
Mode : NORMAL Nx64 Channels : 4
Framing : CRC4 D&I Channels : NOT FITTED
Idle Bandwidth : 1984K System Alarms : None
Clock Reference : INTERNAL * Statistics : Main Link
Configuration : LOCAL Events : Log
Error Counts: >
P
eriod End-----BVC------BER-------CRC------FEBE-------FAS------SYNC
14:33:00 2902 8.9E-06 506 362 94 2
14:48:00 0 <1E-09 0 0 0 0
15:03:00 0 <1E-09 0 0 0 0
15:18:00 0 <1E-09 0 0 0 0
15:33:00 0 <1E-09 0 0 0 0
Current: 15:36:40 0 <1E-09 0 0 0 0
Cursor Keys to move, CTRL-U to save, ESC to abandon
=================================================================================
(S)tart, (E)nd, (^R)eset current, <- / -> = scroll