8
9
USB POWER PORT
1. Push the USB Power Port On/Off Switch to turn the USB Port ON. The USB Power On Indicator
will light to indicate the USB Power Port is ready to use.
2. Lift up the cover of the USB Power Port.
3. Plug the USB-powered device into the USB Power Port and operate normally.
Periodically check the unit's battery status by pressing the Battery Charge Level Button.
Notes:
This unit’s USB Power Port does not support data communication. It only provides 5 volts/500mA DC power to an external USB-
powered device. Make sure the USB Charging Port ON/OFF Pushbutton is in the OFF position when the unit is being recharged or
stored.
Some household USB-powered electronics will not operate with this unit.
12 VOLT DC PORTABLE POWER SUPPLY
This portable power source is also for use with all 12 volt DC accessories equipped with a male
accessory outlet plug and are rated up to 5 amps.
1. Lift up the cover of the unit‘s 12 volt DC outlet.
2. Insert the 12 volt DC plug from the appliance into the 12 volt accessory outlet on the unit. DO NOT
EXCEED A 5 AMP LOAD.
3. Switch on the appliance and operate as usual.
Periodically check the unit's battery status by pressing the Battery Charge Level Button.
Important Note:
The 12VDC accessory outlet will automatically shut down when an overload occurs.
Should this occur, take the following steps:
1. Disconnect all appliances from the 12VDC accessory outlet.
2. Allow the unit to cool down for several minutes.
3. Make sure the rating for all appliances inserted into the 12VDC accessory outlet is below 5A.
4. Assure there is adequate ventilation around the unit before proceeding.
AREA LIGHT
The area light is controlled by the Area Light Power Switch on the front panel of the unit. Make sure
the lamp is turned OFF when the unit is being recharged or stored.
Periodically check the unit's battery status by pressing the Battery Charge Level Button.
TROUBLESHOOTING
Problem
Solution
Unit will not charge
• Make sure all power switches are in the OFF position.
• Make sure a suitable gauge extension cord is properly connected
to both the unit and a functioning AC outlet.
Unit fails to Jump-Start
• Make sure unit’s power switch is in the ON position.
• Check that Jump-Starter has a full charge. Recharge unit if necessary.
• Make sure a proper polarity cable connection has been established.
• Leave charger plugged in and keep unit on charge for 24-48 hours.
Portable Compressor will not
inflate
• Make sure the Compressor Power Switch is in the on position.
• Check that jump-starter has a full charge. Recharge unit if
necessary.
• Make sure connector is pushed to valve stem and thumb latch
is closed when attempting to inflate tires; or nozzle (adapter) is
securely inserted into connector (chuck) on all other inflatables.
• The compressor may be overheated. Press the compressor on/
off button to turn the compressor off. Restart after a cooling
down period of approximately 30 minutes.
12VDC Accessory Outlet will not
power appliance
• Make sure the appliance does not draw more than 5 amps.
• Check that Jump-Starter has a full charge. Recharge unit if
necessary.
WARNINGS
• Jump-Starter Power Switch should be off prior to jump-starting.
• This power system is to be used ONLY on vehicles with 12 volt DC battery systems.
• Never touch red and black clamps together — this can cause dangerous sparks, power arcing, and/
or explosion.
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-
started. Before jump-starting this type of vehicle, read the vehicle manual to confirm that external-
starting assistance is advised.
• Excessive engine cranking can damage the vehicle‘s starter motor. If the engine fails to start after the
recommended number of attempts, discontinue jump-start procedure and look for other problems
that need to be corrected.
• After use, turn the Jump-Starter Power Switch OFF.
PORTABLE COMPRESSOR
The built-in 12 volt DC compressor is the ultimate compressor for all vehicle tires, trailer tires and
recreational inflatables. The compressor hose with tire fitting is stored in a storage compartment
on the back of the unit. The On/Off Switch is located on the front of the unit to the right of the air
pressure gauge. The compressor can operate long enough to fill up to 3 average sized tires before the
battery must be recharged.
The compressor may be used by removing the air hose and SureFit™ nozzle connector from the
storage compartment and if required, fitting an appropriate nozzle adapter to the nozzle connector.
Return the compressor equipment to the storage compartment after use.
WARNING: BURST HAZARD
•
The compressor is capable of inflating up to 120 pounds per square inch (psi) pressure. To avoid
over-inflation, carefully follow instructions on articles to be inflated. Never exceed recommended
pressures. Bursting articles can cause serious injury.
•
Always check pressure with the pressure gauge.
•
Never leave the compressor unattended while in use.
CAUTION: RISK OF PROPERTY DAMAGE
Do not operate compressor continuously for extended periods of time (approximately 10 minutes,
depending on ambient temperatures), as it may overheat. In such event, compressor will automatically
shut down. Immediately turn OFF the Compressor Power Switch. Restart after a cooling down period
of approximately 30 minutes.
INFLATING TIRES OR PRODUCTS WITH VALVE STEMS
1. Screw the SureFit™ nozzle connector onto the valve stem. Do not overtighten.
2. Turn on the compressor power switch.
3. Check pressure with the pressure gauge.
4. When desired pressure is reached, turn off the compressor power switch.
5. Unscrew and remove the SureFit™ nozzle connector from the valve stem.
6. Allow the unit to cool before storing away.
7. Store the compressor hose and nozzle in the storage compartment.
INFLATING OTHER INFLATABLES WITHOUT VALVE STEMS
Inflation of other items requires use of one of the nozzle adapters.
1. Select the appropriate nozzle adapter (i.e, needle).
2. Screw the adapter into the SureFit™ nozzle connector. Do not overtighten.
3. Insert the adapter into item to be inflated.
4. Turn on the compressor power switch — inflate to desired pressure or fullness.
Important!
Small items such as volleyballs, footballs, etc. inflate very rapidly. Do not over-inflate.
5. When desired pressure is reached, turn off the compressor power switch.
6. Disconnect the adapter from the inflated item.
7. Unscrew and remove the adapter from the SureFit™ nozzle connector.
8. Allow the unit to cool before storing away.
9. Store the compressor hose, nozzle and adapter in the storage compartment.
Recharge this unit fully after each use.
WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: FOLLOW ALL SAFETY
INSTRUCTIONS FOUND IN THIS INSTRUCTION MANUAL.
JUS375IBCA_ManualENFR_072915.indd 8-9