4.6
OPERATING INSTRUCTIONS IN ANALOG REMOTE INTERFACE
The Remote analog interface is Provided to control the power supply with
external analog signals.Before using the interface check the type of digital interface
provided with the system.
A slide switch no. 7 on 8 pin DIP switch array is provided at the rear panel to bypass
digital and front panel pot controls.
Ensure the position of slide switch is in off
position when operating with external analog controls.
When GPIB interface is used then internal adjustment is required to bypass the GPIB
interface. Refer to GPIB section of Chapter 6.
Following are the positions of switches for the operating the source in remote mode
by external analog voltage and resistance.
4.6.1 Voltage Programming
Apply the input programming voltage of 0 to 5Volts or 0 to10 Volts between pin 4
& common control pin 6 of 25 pin D type connector for voltage programming & for
current programming between 9 & 6 (common control pin) of 25 pin D-Type connector.
8 pin DIP switch on rear panel:
Switch No.
1
2
3
4
5
6
7
8
Position
Off
Off
Off
Off
off
On
5 = ON for 0-5V programming
5 = OFF for 0-10V programming
6 = OFF for 0-5V monitoring
6 = ON for 0-10V monitoring
Refer fig. 4.1a for remote voltage and current programming and monitoring
It also explains load connections required in this mode.
Note: Factory set for 0 to 5 volts for full scale output programming and moni-
toring.
4.6.2 Resistance Programming
For resistance programming standard resistor used is 4.85KOhms.
Following shows the DIP switch configuration required in this mode & explains the
connection of the resistor to the 25 pin D-type connector.
8 pin DIP switch on rear panel:
Switch No.
1
2
3
4
5
6
7
8
Position
Off
On
Off
On
On
off
On
6 = OFF for 0-5V monitoring
6 = ON for 0-10V monitoring
17
Содержание VSP12010
Страница 1: ...MODELS VSP6020 VSP2050 VSP4030 VSP12010 High Power Switching DC Power Supplies Instruction Manual...
Страница 14: ...12...
Страница 42: ...SCPI STATUS SYSTEM 40...