Pin no.14:
N.C.
Pin no.15:
+12 V- Remote on/off relay ve.
Pin no.16:
AGND3 - Common terminal for remote programming.
Pin no.17:
Remote On/Off - Remote on/off relay.
Pin no.18:
AMX- Output Current monitoring. (Factory set to 0 to 5 volts for full scale)
Pin no.19:
VMX - Output Voltage monitoring. (Factory set to 0 to 5 volts for full scale)
Pin no. 20:
AGND3 - Common terminal for remote monitoring.
Pin no. 21:
N.C.
Pin no. 22:
VPSET - External programming option set for output voltage.
Pin no. 23:
VMSET -External-monitoring option set for monitoring the output voltage.
Pin no. 24:
IPSET - External programming option set for output current.
Pin no. 25:
IMSET - External monitoring option set for current.
4.3.6
DIP SWITCH DETAILS.
DIP Switch is provided on the rear panel to facilitates remote analog interface as
well as local mode interface in the power supply by just changing the switch positions
Switch no. 1 & 2 are associated with voltage programming
Switch no. 3 & 4 are associated with current programming
Switch no. 5 is associated with 0-5V & 0-10V programming
Switch no. 6 is associated 0-5V & 0-10V monitoring
Switch no. 7 is Local/RS232 and Analog interface selection
Switch no. 8 is associated with remote ON-OFF.
4.3.7 DIGITAL COMMUNICATION INTERFACE (optional)
Digital communication interface either GPIB or RS-232 interface can be incor-
porated with the system as per the order placed. As per the ordered digital communi-
cation interface, the slots are available on the rear panel
The slide switch no. 7 on 8 pin DIP switch array selects the LOCAL/RS232 or Analog
interface & 9 pin D-Type connector is provided on rear panel to connect the unit to PC.
NOTE:
Refer Chapter 5 For Details Of Digital Communication Interface.
4.4
POWER ON CHECK
Keep the DIP switch settings for local mode operation. (Refer to 4.5)
After switching ON the unit, the display will show the actual voltage and current at the
output if output ON/OFF switch is in pressed position. If the switch is in OFF position
then the output voltage goes to 0V & displays zero. Also LED associated with key
shows the condition of output. If TRIP LED is ON then display show zero values and
LED associated with ON/OFF key remains off.
15