90
before using any of these commands to control that unit’s output.
Command
Description
CPV
Set the output voltage value in Volts
CPV?
Read the output voltage setting
CMV?
Read the actual output voltage
CPC
Set the output current value in Amperes
CPC?
Read the output current setting
CMC
Read the actual output current
CDVC?
Display voltage and current data
COUT
Turn the output to ON or OFF
COUT?
Return the output On/Off status
COV
Set the OVP level
COV?
Return the OVP setting level
COVP
Set the OVP on/off
COVP?
Return the OVP on/off
COC
Set the OCP level
COC?
Return the OCP setting level
COCP
Set the OCP on/off
COCP?
Return the OCP on/off
COP
Set the OPP level
COP?
Return the OPP setting level
COPP
Set the OPP on/off
COPP?
Return the OPP on/off
CMODE?
Return the power supply operation mode
Synchronous control commands