41
20H Set the Remote control mode
21H Set the input on/off state
22H Set the max input voltage
23H Read the max setup input voltage.
24H Set max input current
25H Read the max setup input current.
26H Set max input power.
27H Read the max setup input power.
28H Set CC/CV/CW/CR operation mode of electronic load.
29H Read the operation mode.
2AH Set CC mode current value
2BH Read CC mode current value
2CH Set CV mode voltage value
2DH Read CV mode voltage value
2EH Set CW mode watt value
2FH Read CW mode watt value
30H Set CR mode resistance value
31H Read CR mode resistance value
32H Set CC mode transient current and timer parameter.
33H Read CC mode transient parameter
34H Set CV mode transient voltage and timer parameter.
35H Read CV mode transient parameter
36H Set CW mode transient watt and timer parameter
37H Read CW mode transient parameter
38H Set CR mode transient resistance and timer parameter
39H Read CR mode transient parameter
3AH Set the list operation mode (CC)
3BH Read the list operation mode.
3CH Set the list repeat mode (ONCE/REPEAT)
3DH Read the list repeat mode.
3EH Set list steps counts.
3FH Read list steps counts
40H Set one of the step’s current and time values.
41H Read one of the step’s current and time values.
4CH Save list file in appointed area.
4DH Recall the list file from the appointed area.
50H Set timer value of FOR LOAD ON
51H Read timer value of FOR LOAD ON
52H Disable/Enable timer of FOR LOAD ON
53H Read timer state of FOR LOAD ON
54H Set communication address
55H Enable/Disable LOCAL control button.
56H Enable/Disable remote sense mode.
57H Read the state of remote sense mode.
58H Set trigger source.
59H Read trigger source.
5AH Sending a trigger signal to trigging the electronic load.
5BH Saving user’s setting value in appointed memory area for recall.
5CH Recall user’s setting value in appointed memory area.
5DH Set function mode (FIXED/SHORT/TRAN/LIST/BATTERY).
5EH Read function mode state.
5FH enquire input voltage, current, power and relative state
01H Read the information of E-Load (rated current/voltage, min voltage, max power, max resistance, min resistance)
02H Set hardware OPP point
03H Read hardware OPP point
80H Set software OCP point
81H Read software OCP point
82H Set OCP delay time
83H Read OCP delay time
84H Enable/disable OCP function
85H Read the state of OCP function
86H Set software OPP point
87H Read software OPP point
88H Set software OPP delay time
89H Read software OPP delay time
8AH Set the first measured point
8BH Read the first measured point
8CH Set the second measured point
8DH Read the second measured point
8EH Set Vd value of CR-LED mode
8FH Read Vd value of CR-LED mode
90H Clear the protection state
91H Enable/disable voltage autorange function
92H Read the state of voltage autorange
93H Enable/disable CR-LED function
94H Read the state of CR-LED mode
9DH Provide a trigger signal, nomatter what the current trigger source it is.
A0H Read related information of E-load (working time, the rest time of the timer)
A1H Read related information of E-load (max input voltage and current, min input votage and current)
A2H Read the max measured voltage in list mode
A3H Read the min measured voltage in list mode
A4H Read the max measured current in list mode
A5H Read the min measured current of E-load
A6H enquire the capacitance
B0H Set current rising slope
B1H Read current rising slope
B2H Set current falling slope
B3H Read current falling slope
B4H Set the voltage upper limit in CC mode
B5H Read the voltage upper limit in CC mode
B6H Set the voltage lower limit in CC mode
B7H Read the voltage lower limit in CC mode
B8H Set the current upper limit in CV mode
B9H Read the current upper limit in CV mode
BAH Set the current lower limit in CV mode
BBH Read the current lower limit in CV mode
BCH Set the voltage upper limit in CP mode
BDH Read the voltage upper limit in CP mode
BEH Set the voltage lower limit in CP mode
BFH Read the voltage lower limit in CP mode
C0H Set the max input resistance
C1H Read the max input resistance
C2H Set the voltage upper limit in CR mode
C3H Read the voltage upper limit in CR mode
C4H Set the voltage lower limit in CR mode
C5H Read the voltage lower limit in CR mode
C6H Set the current range in list mode
C7H Read the current range in list mode
D0H Set step counts of autotest file
D1H Read step counts of autotest file
D2H Set short steps
D3H Read short steps
D4H Set pause steps
D5H Read pause steps
D6H Set the on-load time of single step
D7H Read the on-load time of single step
D8H Set the delay time of single step
D9H Read the delay time of single step
DAH Set the no-load time of single step
DBH Read the no-load time of single step
DCH Set autotest stop condition
DDH Read autotest stop condition
DEH Set autotest chain file
DFH Read autotest chain file
E0H Save autotest file
E1H Recall autotest file
0EH Set Von mode
0FH Read Von mode
10H Set Von point
11H Read Von point