background image

13

KB-510-3

13

5.1 Strength pressure test

Evaluate the refrigerant circuit (as-
sembly) according to EN 378-2 (or
valid equivalent safety standards). The
compressor had been already tested
in the factory for strength pressure.
Therefore a tightness test (5.2) is suf-
ficient.

However, if the whole assembly is test-
ed for strength pressure:

Danger!
Test pressure may not exceed
the maximum operating pres-
sures indicated on the name
plate!
If necessary leave the shut-off
valves closed!

5.2 Tightness test

Evaluate tightness of the entire refrig-
erant circuit (assembly) or parts of it –
according to EN 378-2 (or valid equiv-
alent safety standards) by using pre-
ferably an overpressure of dry nitro-
gen.

Danger!
Test pressures and safety refer-
ences see chapter 5.1.

5.3 Evacuation

Energize the crankcase heater.

Open all shut-off valves and solenoid
valves. Evacuate the entire system
including compressor using a vacuum
pump connected to the high and low
pressure sides.
When the pump is switched off a
"standing vacuum" of less than
1.5 mbar must be maintained.
If necessary repeat this procedure
several times.

Attention!
Do not start compressor under
vacuum.
Mechanical damages possible.
Charge refrigerant first!

!

!

5.1 Essayer la résistance à la pression

Essayer le circuit frigorifique (groupe as-
semblé) correspondant à EN 378-2 (ou
normes de sécurité équivalentes, qui sont
valables). Le compresseur était déjà
essayé à l'usine sur son résistance à la
pression. Par ça un essai d'étanchéité
(5.2) est suffisiant.

En cas d'essayer néanmoins la résistance
à la pression du tout le groupe assemblé:

Danger !
Le timbrage ne doit pas excéder 
les pressions de service maximales
qui sont marquées sur la plaque
d'identité !
En cas utile laisser les vannes d'ar-
rêt fermées !

5.2 Essayer l'étanchéité

Essayer tout le circuit frigorifique (groupe
assemblé) ou des parties – conformé-
ment à EN 378-2 (ou normes de sécurité
équivalentes, qui sont valables). Utiliser
préféremment une surpression avec de
l'azote séché.

Danger !
Timbrages et indications de sécurité
voir chapitre 5.1.

5.3 Tirage à vide

Mettre la résistance de carter en service.

Ouvrir les vannes d'isolement et les
vannes magnétiques existantes. Procéder
à la mise sous vide de l'ensemble du sys-
tème, y compris le compresseur, à l'aspi-
ration et au refoulement.
Un "vide stable" inférieur à 1,5 mbar doit
se maintenir après l'arrêt de la pompe à
vide.
En cas utile répéter plusieurs fois la pro-
cédure.

Attention !
Ne pas démarrer le compresseur
sous vide.
Des défauts mécaniques sont pos-
sibles.
Procéder d'abord au remplissage de
fluide frigorigène !

!

!

5.1 Druckfestigkeit prüfen

Kältekreislauf (Baugruppe) entspre-
chend EN 378-2 prüfen (oder gültigen
äquivalenten Sicherheitsnormen). Der
Verdichter wurde bereits im Werk
einer Prüfung auf Druckfestigkeit
unterzogen. Eine Dichtheitsprüfung
(5.2) ist deshalb ausreichend.

Wenn dennoch die gesamte Baugrup-
pe auf Druckfestigkeit geprüft wird:

Gefahr!
Prüfdruck des Verdichters darf
die maximal zulässigen Drücke
nicht überschreiten, die auf dem
Typschild genannt sind!
Bei Bedarf Absperrventile
geschlossen halten!

5.2 Dichtheit prüfen

Kältekreislauf (Baugruppe) als Gan-
zes oder in Teilen auf Dichtheit prüfen
– entsprechend EN 378-2 (oder gülti-
gen äquivalenten Sicherheitsnormen).
Dazu vorzugsweise mit getrocknetem
Stickstoff einen Überdruck erzeugen.

Gefahr!
Prüfdrücke und Sicherheits-
hinweise siehe Kapitel 5.1.

5.3 Evakuieren

Ölsumpfheizung einschalten.

Vorhandene Absperr- und Magnet-
ventile öffnen. Das gesamte System
einschließlich Verdichter auf Saug-
und Hochdruckseite mit Vakuumpum-
pe evakuieren.
Bei abgesperrter Pumpenleistung
muss ein "stehendes Vakuum" kleiner
als 1,5 mbar erreicht werden.
Wenn nötig Vorgang mehrfach wieder-
holen.

Achtung!
Verdichter nicht im Vakuum star-
ten!
Mechanische Schäden möglich.
Zuerst mit Kältemittel befüllen!

!

!

Содержание KB-510-3

Страница 1: ...stalled in these machines according to the existing instruction and as a whole agree with the corresponding provisions of legislation standards to apply refer to Manufacturers Declara tion Authorized...

Страница 2: ...es en danger Respecter scrupuleusement les indica tions de s curit Attention Instruction pour viter une possible mise en danger d appareils Prudence Instruction pour viter une possible mise en danger...

Страница 3: ...0 C pourront tre atteintes Des graves brulures et gelures sont possible Possibilit de graves brulures Fermer et marquer les endroits accessibles Avant les travaux au compresseur Ar tter et refroidir c...

Страница 4: ...t e Avertissement En cas d introduction d air disloca tion critique de la limite d inflamma bilit de fluide frigorig ne Eviter absolument introduction d air 3 Montage 3 1 Transport du compresseur Tran...

Страница 5: ...ion Flexible instal lation to reduce structurally trans mitted noise is also possible float ing foundation or vibration dampers If vibration dampers with single point support are used a reinforced fra...

Страница 6: ...let e du c t du compresseur La rondelle ressort et l crou tant l g rement viss Enfoncer la clavette par quelques coups de marteau l gers Visser l crou Attention Danger de une fissure du moyeu Eviter d...

Страница 7: ...section down 17 mm for every 1000 mm free belt length Recommended power P width 13 mm 11 to 16 N width 17 mm 22 to 31 N The belt tension must be checked again after a running in period Attention Do no...

Страница 8: ...If not required the end with the largest diameter can be cut off Attention Do not overheat the valves Cool valve body while and after brazing Max brazing temperature 700 C 3 5 Raccordements de tuyaut...

Страница 9: ...tive connection for oil and gas equilization parallel oper ation 7 Pressure gauge connection HP 8 Pressure gauge connection LP 9 Cooling water connection IIIW Y VIIW Y 10 Pressure relief valve VIIW Y...

Страница 10: ...ce 4 Electrical connection 4 1 General recommendations The electrical accessory is in accor dance with the EC Low Voltage Directive 73 23 EEC CE 96 The electrical installation is to be car ried out ac...

Страница 11: ...iteurs de pression HP LP sont n cessaires pour d limiter la plage de fonctionnement du compresseur de fa on ce que des conditions de fonc tionnement inadmissibles soient exclues Position des raccords...

Страница 12: ...essure and the tightness of the entire plant preferably with dry nitrogen N2 Compressor must be put out of circuit when using dried air keep the shut off valves closed Gefahr By no means the compresso...

Страница 13: ...rifique groupe assembl ou des parties conform ment EN 378 2 ou normes de s curit quivalentes qui sont valables Utiliser pr f remment une surpression avec de l azote s ch Danger Timbrages et indication...

Страница 14: ...he suction side while the compressor is in operation Charge preferably at the evaporator inlet Blends must be taken from the charging cylinder as solid liquid If liquid is charged Attention Danger of...

Страница 15: ...rtan tes d huile dans le circuit p ex la suite d un d faut du compresseur il existe un danger suppl mentaire de coups de liquide au d marrage Ajuster le niveau d huile dans la plage indiqu e sur le vo...

Страница 16: ...lary tubes must be checked for abnormal vibrations If necessary additional protective mea sures must be taken Attention Pipe fractures and leakages at compressor and other compo nents of the plant pos...

Страница 17: ...n initiale des courroies apr s la p riode de rodage V rifier les raccords des c bles lec triques sur ajustement solide 6 2 Clapets sont dimensionn s pour un service sans entretien Il est n anmoins con...

Страница 18: ...very 3 years or 10 12 000 operating hours Clean also oil filter and magnetic plug Oil types See chapter 2 Oil quantity 0 Y I Y level until connection 3 see page 10 II Y VII W Y until middle of sight g...

Страница 19: ...ence de stries et de d p ts de mati re de calamine et de cuivre sur les bagues de glisse ment 6 4 Wellenabdichtung Eine routinem ige berpr fung der Wellenabdichtung ist im Regelfall nicht erforderlich...

Страница 20: ...ion Le d montage du volant suffit Rel cher la courroie trap zo dale Retirer l crou et la clavette filet e Retirer le volant de l arbre Fermer les vannes d arr t du compres seur Avertissement Compresse...

Страница 21: ...gue de glis sement tournante 9 sur l arbre Repousser l arbre vers l int rieur en le tournant Mettre le plus grand joint nouveau 11 et la bague de glissement statique dans l videment du couvercle lat r...

Страница 22: ...efrigerant but dispose it properly Warning Compressor can be under pressure Severe injuries possible Wear safety goggles Open the threaded joints or flanges at the compressor valves Remove the compres...

Страница 23: ...23 KB 510 3...

Страница 24: ...lten Subject to change Toutes modifications r s rv es 04 03 Bitzer K hlmaschinenbau GmbH Eschenbr nnlestr 15 71065 Sindelfingen Germany Tel 49 0 7031 932 0 Fax 49 0 7031 932 146 147 bitzer bitzer de h...