Description 

 
 
The Bioscrypt Veri-Series Outdoor Enclosure is designed to protect the Veri-Series 

fingerprint readers from extreme weather conditions and direct contact with the 
elements, including rain, sun, snow, sand or excessive moisture. The Outdoor 

Enclosure is lightweight, durable, watertight, and non-corroding. 
 
The Outdoor Enclosure is manufactured from hot compression-molded fiberglass 
reinforced polyester (FRP) and is UL listed and CSA certified for a NEMA rating of 3, 3R, 

4, 4X, 12 and 13. It is additionally Halogen-free and designed in accordance with the 
Joint Industrial Council (JIC) – USA. 
 

The Outdoor Enclosure contains a top stainless steel piano hinge and a standard 
latch at the bottom which may be secured with a padlock. It is NOT necessary to 

engage the bottom latch after every use for installations that do not require NEMA 
certified rating.
 However, to enforce the NEMA ratings and properly seal the door, this 
latch must be engaged after every use. It is also recommended that the latch be 
engaged after every use under extreme weather conditions (i.e., strong winds and/or 

heavy rains). 
 

The Outdoor Enclosure optionally includes a bonded window designed for Veri-Series 
fingerprint readers that are not in direct sun (i.e., installed under an awning, patio, 

overhang, etc.).  

 
The Outdoor Enclosure shall optionally include a heater and thermostat designed to 
maintain the Veri-Series fingerprint reader at an ambient temperature of 
approximately 24

°

 C (75

°

 F). The heater shall require an external power supply, sold 

separately. The Outdoor Enclosure can withstand continuous temperatures of up to -
50

°

 C to 150

°

 C (-58

°

 F to 302

°

 F) and momentary temperatures to 200

°

 C (392

°

 F). 

 
Overall, the Bioscrypt Veri-Series Outdoor Enclosure shall measure 11.31” x 9.31” x 
5.43” (287 x 236 x 138 mm). The Enclosure shall be comprised of:  

 

 

The Enclosure body 

 

Heater and Thermostat (optional) 

 

Sub Panel 

 

Roxtec Gland M63 seal 

 

Содержание VENC

Страница 1: ...Document 430 00146 01 Copyright 2003 2005 Bioscrypt Inc All rights reserved V ENC Enclosure Installation Guide Veri Series Outdoor Enclosure Models VENC VTENC VNENC March 23 2005...

Страница 2: ...within such an enclosure shall void the warranty on the fingerprint reader The Veri Series product line includes V Prox V Flex V Pass V Smart MIFARE and iCLASS models V Station Base Searching Prox MIF...

Страница 3: ...e mail your comments to support bioscrypt com or contact Bioscrypt Technical Support at the telephone number listed below Bioscrypt accepts no liability for the misuse of third party hardware mention...

Страница 4: ...tion RMA number No product may be returned whether in warranty or out of warranty without first obtaining approval from Bioscrypt The model number invoice number and serial number may be required for...

Страница 5: ...g from exposure to these conditions are not covered under the product warranty For outdoor installations Bioscrypt does offer an enclosure to protect the device from exposure to moisture dust other co...

Страница 6: ...allations that do not require NEMA certified rating However to enforce the NEMA ratings and properly seal the door this latch must be engaged after every use It is also recommended that the latch be e...

Страница 7: ...V Smart Solid No VTENC W V Smart Window No VTENC Ht V Smart Solid Yes VTENC W Ht V Smart Window Yes VNENC V Station Solid No VNENC W V Station Window No VNENC Ht V Station Solid Yes VNENC W Ht V Stat...

Страница 8: ...that at least one vertical pair of mounting holes is secured to a stud A schematic has been provided in Figure 1 which displays the rear mounting surface of the enclosure and its dimensions The rear...

Страница 9: ...mplete please follow the steps below to install the seal into the enclosure Please refer to the Assembly Instruction Roxtec Gland M63 sheet provided with the seal for visual representations of the ste...

Страница 10: ...ide the frame around and between the module halves etc Start by placing a module half at the bottom Place the cables in the adapted modules Add the second module half on top Add the next module and co...

Страница 11: ...ermostat Connect the Power Supply Positive to the thermostat Please refer to Figure 2 for a wiring diagram Figure 2 Heater and Thermostat Connection Assembling the Sub Panel Once the cables have been...

Страница 12: ...er Feed the DB15 Conductor Pigtail Weidmuller RJ45 Ethernet RJ45 RS 485 or RJ11 RS 232 cables through the Sub Panel and Veri Series Wall Mount access hole Mount the Sub Panel to the Outdoor Enclosure...

Страница 13: ...oor Enclosure Attach the 15 Conductor Pigtail Weidmuller Connectors RJ45 and or RJ11 cables to the Veri Series fingerprint reader body or fingerprint verification module on the V Smart For the V Smart...

Страница 14: ...udes a latch Please note that this latch must be engaged after every use to properly seal the door and enforce the NEMA ratings It is NOT necessary to engage the bottom latch after every use for insta...

Страница 15: ...Fax 818 304 7187 E mail support bioscrypt com Web http www bioscrypt com Version Number 2 Date March 23 2005 Corporate Canadian Office 5450 Explorer Drive Suite 500 Mississauga ON Canada L4W 5M1 T 90...

Отзывы: