All Veri-Series units have an operating temperature range of 0

°

-60

°

 Celsius (32

°

-140

°

 

Fahrenheit). In addition, the Veri-Series product line has a relative humidity operating 

range of 0-95% non-condensing.  Any device used outside that temperature or 
humidity range requires an enclosure with thermal or humidity control that can 

maintain a consistent environment within the stated operating ranges. 

 
The newest Bioscrypt Veri-Series products are designed to be weather resistant but no 

sensor technology exists today that can work in all weather environments. If a 

Bioscrypt Veri-Series product is not used in a completely indoor environment, then a 
protective enclosure is required to shield the unit from moisture, dust, other 

contaminants and temperatures outside stated operating range.  Product failures 
resulting from exposure to these conditions are not covered under the product 

warranty. 
 

For outdoor installations, Bioscrypt does offer an enclosure to protect the device from 
exposure to moisture, dust, other contaminants and temperatures outside stated 
operating range.  When used properly, this enclosure will protect Veri-Series devices 

in most environments, but not all.  The Customer is responsible for determining 
whether the offered enclosure will appropriately shield Veri-Series devices in their 

specific installation.  Product failures resulting from exposure to moisture, dust, other 
contaminants and temperatures outside stated operating range, even if an 

enclosure is used, are not covered under the product warranty.

 

 

This warranty is exclusive and in lieu of all others, whether oral or written, expressed or 
implied.  Bioscrypt specifically disclaims any and all implied warranties, including 
without limitation, warranties of merchantability and fitness for any particular 

purpose. No Bioscrypt dealer, agent, or employee is authorized to make any 
modification, extension or addition to this warranty.

   

Содержание VENC

Страница 1: ...Document 430 00146 01 Copyright 2003 2005 Bioscrypt Inc All rights reserved V ENC Enclosure Installation Guide Veri Series Outdoor Enclosure Models VENC VTENC VNENC March 23 2005...

Страница 2: ...within such an enclosure shall void the warranty on the fingerprint reader The Veri Series product line includes V Prox V Flex V Pass V Smart MIFARE and iCLASS models V Station Base Searching Prox MIF...

Страница 3: ...e mail your comments to support bioscrypt com or contact Bioscrypt Technical Support at the telephone number listed below Bioscrypt accepts no liability for the misuse of third party hardware mention...

Страница 4: ...tion RMA number No product may be returned whether in warranty or out of warranty without first obtaining approval from Bioscrypt The model number invoice number and serial number may be required for...

Страница 5: ...g from exposure to these conditions are not covered under the product warranty For outdoor installations Bioscrypt does offer an enclosure to protect the device from exposure to moisture dust other co...

Страница 6: ...allations that do not require NEMA certified rating However to enforce the NEMA ratings and properly seal the door this latch must be engaged after every use It is also recommended that the latch be e...

Страница 7: ...V Smart Solid No VTENC W V Smart Window No VTENC Ht V Smart Solid Yes VTENC W Ht V Smart Window Yes VNENC V Station Solid No VNENC W V Station Window No VNENC Ht V Station Solid Yes VNENC W Ht V Stat...

Страница 8: ...that at least one vertical pair of mounting holes is secured to a stud A schematic has been provided in Figure 1 which displays the rear mounting surface of the enclosure and its dimensions The rear...

Страница 9: ...mplete please follow the steps below to install the seal into the enclosure Please refer to the Assembly Instruction Roxtec Gland M63 sheet provided with the seal for visual representations of the ste...

Страница 10: ...ide the frame around and between the module halves etc Start by placing a module half at the bottom Place the cables in the adapted modules Add the second module half on top Add the next module and co...

Страница 11: ...ermostat Connect the Power Supply Positive to the thermostat Please refer to Figure 2 for a wiring diagram Figure 2 Heater and Thermostat Connection Assembling the Sub Panel Once the cables have been...

Страница 12: ...er Feed the DB15 Conductor Pigtail Weidmuller RJ45 Ethernet RJ45 RS 485 or RJ11 RS 232 cables through the Sub Panel and Veri Series Wall Mount access hole Mount the Sub Panel to the Outdoor Enclosure...

Страница 13: ...oor Enclosure Attach the 15 Conductor Pigtail Weidmuller Connectors RJ45 and or RJ11 cables to the Veri Series fingerprint reader body or fingerprint verification module on the V Smart For the V Smart...

Страница 14: ...udes a latch Please note that this latch must be engaged after every use to properly seal the door and enforce the NEMA ratings It is NOT necessary to engage the bottom latch after every use for insta...

Страница 15: ...Fax 818 304 7187 E mail support bioscrypt com Web http www bioscrypt com Version Number 2 Date March 23 2005 Corporate Canadian Office 5450 Explorer Drive Suite 500 Mississauga ON Canada L4W 5M1 T 90...

Отзывы: