Page 11
Document# 430-00146-01
© Copyright 2003 - 2005, Bioscrypt Inc. All rights reserved.
o
Weidmuller Connectors (for use with V-Station)
o
RJ45 Ethernet, RJ45 RS-485 or RJ11 RS-232 Ports (for use with V-Station)
o
Connect the Earth Ground cable to one of the four Sub Panel metal
posts (cable to be spliced and shared with Veri-Series fingerprint reader).
Feed the DB15-Conductor Pigtail, Weidmuller, RJ45 Ethernet, RJ45 RS-485 or
RJ11 RS-232 cables through the Sub Panel and Veri-Series Wall Mount access
hole.
Mount the Sub Panel to the Outdoor Enclosure by securing it to the four metal
posts.
Adjust the slack of the cables by pulling excess slack out of the Outdoor
Enclosure away from the seal gland housing.
A schematic has been provided in Figure 3 which displays the assembly of the Roxtec
Gland M63 seal and Sub Panel.
Figure 3: Roxtec Gland & Sub Panel Assembly
Mounting the Outdoor Enclosure