be dedicated to the heater and thermostat and not be shared with the Veri-Series
fingerprint reader. This power supply is not provided with the Outdoor Enclosure and
must be purchased separately. Additionally, general good practice allows the power
to flow through the switch to the powered device, though not mandatory.
To properly connect the heater and thermostat, the following steps are required:
Connect one conductor from the heater to Power Ground.
Connect the second conductor from the heater to the thermostat.
Connect the Power Supply Positive to the thermostat.
Please refer to Figure 2 for a wiring diagram.
Figure 2: Heater and Thermostat Connection
Assembling the Sub Panel
Once the cables have been pulled through into the Outdoor Enclosure, the Roxtec
Gland M63 seal is in place, and the heater has been powered, the Sub Panel of the
Outdoor Enclosure shall need to be reassembled by following the steps listed below:
Remove the protective film from the stainless steel Sub Panel.
Remove the four wall mount screws from the Sub Panel (located around the
Sub Panel access hole) and use them to secure the Veri-Series Wall Mount to
the Sub Panel.
Create the connections from the cables to the Veri-Series reader and Sub
Panel:
o