It is best to mount the Outdoor Enclosure to the wall before the Veri-Series Fingerprint 
reader is mounted within the enclosure.  

 
The Outdoor Enclosure shall be designed to mount directly to any solid surface 

including a wall anchor, wood, sheet metal, or dry wall. When mounting on drywall, 

please ensure that at least one vertical pair of mounting holes is secured to a stud. 
 

Using 4 screws with a thread type no larger than 5/16”, mount the Outdoor Enclosure 

to the wall so that the Roxtec Gland M63 seal fits into the access hole that was 
created earlier in the wall. Please refer to Figure 1 which displays the rear-mounting 

surface of the enclosure and its dimensions. 
 

Finally, if installing an Outdoor Enclosure that includes the optional bonded window, 
please remove the protective film from the bonded window at this time. 

 

Mounting the Veri-Series Fingerprint Reader

 

 
Follow the steps listed below to mount the Veri-Series fingerprint reader to the 
Outdoor Enclosure: 

 

 

Attach the 15-Conductor Pigtail, Weidmuller Connectors, RJ45 and/or RJ11 
cables to the Veri-Series fingerprint reader body (or fingerprint verification 
module on the V-Smart).  

 

For the V-Smart reader, additionally connect the Molex connection to the 

smart card interface module. 

 

Slide the Veri-Series fingerprint reader body into the Veri-Series Wall Mount using 
the tabs located on the rear of the reader. 

 

Secure the Veri-Series fingerprint reader body to the Veri-Series Wall Mount 
using the #4-40 inch screw(s) provided with the reader. 

 

Snap the RJ11 security cover into place: 

With the textured side facing down, place the left tab into the left corner 
groove on the reader body. 

Rotate the cover until the right tab easily slides into the groove. 

With the tab in the reader body groove, rotate the cover clockwise until 
the right tab snaps into place at the right rear corner. 

Fold the cover up and secure it using the supplied pin-in-hex security 
screw and Allen wrench. 

 
The Veri-Series fingerprint reader is now ready for use outdoors. When a user needs to 
access the reader, simply lift the front lid and initialize the verification. Once the 
verification is complete the lid may be closed once more. The Outdoor Enclosure 

Содержание VENC

Страница 1: ...Document 430 00146 01 Copyright 2003 2005 Bioscrypt Inc All rights reserved V ENC Enclosure Installation Guide Veri Series Outdoor Enclosure Models VENC VTENC VNENC March 23 2005...

Страница 2: ...within such an enclosure shall void the warranty on the fingerprint reader The Veri Series product line includes V Prox V Flex V Pass V Smart MIFARE and iCLASS models V Station Base Searching Prox MIF...

Страница 3: ...e mail your comments to support bioscrypt com or contact Bioscrypt Technical Support at the telephone number listed below Bioscrypt accepts no liability for the misuse of third party hardware mention...

Страница 4: ...tion RMA number No product may be returned whether in warranty or out of warranty without first obtaining approval from Bioscrypt The model number invoice number and serial number may be required for...

Страница 5: ...g from exposure to these conditions are not covered under the product warranty For outdoor installations Bioscrypt does offer an enclosure to protect the device from exposure to moisture dust other co...

Страница 6: ...allations that do not require NEMA certified rating However to enforce the NEMA ratings and properly seal the door this latch must be engaged after every use It is also recommended that the latch be e...

Страница 7: ...V Smart Solid No VTENC W V Smart Window No VTENC Ht V Smart Solid Yes VTENC W Ht V Smart Window Yes VNENC V Station Solid No VNENC W V Station Window No VNENC Ht V Station Solid Yes VNENC W Ht V Stat...

Страница 8: ...that at least one vertical pair of mounting holes is secured to a stud A schematic has been provided in Figure 1 which displays the rear mounting surface of the enclosure and its dimensions The rear...

Страница 9: ...mplete please follow the steps below to install the seal into the enclosure Please refer to the Assembly Instruction Roxtec Gland M63 sheet provided with the seal for visual representations of the ste...

Страница 10: ...ide the frame around and between the module halves etc Start by placing a module half at the bottom Place the cables in the adapted modules Add the second module half on top Add the next module and co...

Страница 11: ...ermostat Connect the Power Supply Positive to the thermostat Please refer to Figure 2 for a wiring diagram Figure 2 Heater and Thermostat Connection Assembling the Sub Panel Once the cables have been...

Страница 12: ...er Feed the DB15 Conductor Pigtail Weidmuller RJ45 Ethernet RJ45 RS 485 or RJ11 RS 232 cables through the Sub Panel and Veri Series Wall Mount access hole Mount the Sub Panel to the Outdoor Enclosure...

Страница 13: ...oor Enclosure Attach the 15 Conductor Pigtail Weidmuller Connectors RJ45 and or RJ11 cables to the Veri Series fingerprint reader body or fingerprint verification module on the V Smart For the V Smart...

Страница 14: ...udes a latch Please note that this latch must be engaged after every use to properly seal the door and enforce the NEMA ratings It is NOT necessary to engage the bottom latch after every use for insta...

Страница 15: ...Fax 818 304 7187 E mail support bioscrypt com Web http www bioscrypt com Version Number 2 Date March 23 2005 Corporate Canadian Office 5450 Explorer Drive Suite 500 Mississauga ON Canada L4W 5M1 T 90...

Отзывы: