IP of 255.255.255.255 will prohibit emails to be sent out.
1)
Directly setup the IP to SMTP server
This is most effective way to issue email alert. However Gateway address might be necessary if
SMPT server is not within the same LAN domain. (See Basic Parameter, Setup page) At the same
time, this will expose the DVPro T10 to external network environment resulted in security issue.
2)
Assign local SMTP Server
If there is no need for authentication, you can forward (relay) from DVPro T10 notification by
setting up the local SMPT server. For Windows OS, you can setup IP address of DVPro T10 on
SMPT which has the RELAY function.
●
Send Test Mail
(
button
)
By clicking on
“Send Test Mail” button following the email setup, you can send a test email to the
receiver address for confirmation.
<
A failed screen
>
There will be
“Sending Test Mail” shown on the screen indicating the email in transmission. And the log
will record a message if the test mail was sent out. If the Send Test Main failed after retried, an error
log will be recorded.
0020: SMTP was not found
0021: Gateway was not found
0022: SMTP did not respond
It might take up to 10 minutes for the retrial if the mail could not be sent.
There might be cases which SMTP did respond but with wrong answer. We suggest trying a different
SMTP server under such situation.
2.6.5 Mail Format
The mail format is looked like below:
From:
DVPro@[192.168.50.210]
Содержание DVPro DVT10T2
Страница 2: ......
Страница 5: ...DVT10T2 2...
Страница 9: ...DVT10T2 6 Rear View Side View...
Страница 37: ...DVT10T2 34 Additional RAID parameters...
Страница 56: ...BIOS AP Inc 53 2 8 3 IP Setup for MAC OS X Click System Preferences Click Network Icon...
Страница 58: ...BIOS AP Inc 55...
Страница 64: ...BIOS AP Inc 61 The New Volume Wizard will load up so click Next Choose the volume you want then click Next...