Temperature»,
, and press the encoder button – the Controller will display the pump
menu (Picture 20).
Parameter value change is similar to item 3.3.3.
Parameter value limits:
pump switch-on temperature, °С:
40-80;
pump switch-off hysteresis, °С:
1-10.
Picture 20 – Pump Parameter Change Window
Pump switch-on temperature is changed in this window. Central Heating pump
and Hot Water Supply pump switch on only once the preset temperature is achieved,
and switch off when water temperature in boiler drops lower than the set temperature of
switch-on minus hysteresis.
!ATTENTION!
Pump switch-on temperature cannot exceed the temperature set in the boiler. Under
such conditions pumps will never switch on.
!ATTENTION!
Pumps operation is also adjusted by the selected boiler operation priority, see item 3.5