system. (This function is used in summer time only. This function is impossible if the
hot water supply temperature sensor is not hooked up to the controller).
2.4 Boiler Temperature Adjustment (hot water supply)
For changing boiler heating parameters it is required to go to the Controller
menu (Picture 6):
Picture 6 – Controller Menu
By turning an encoder dial, select icon,
, «Hot Water Supply Setting».
When pressing on a dial the boiler setting menu will open (Picture 7).
Hot Water Supply operating parameters are set in this menu. Boiler heating
temperature - from 40°С to 80 °С, with a step of 1°С; pump hysteresis – 1°С to 10°С,
with a step of 1°С.
Picture 7 – Hot Water Supply Parameter Menu