13
EXIT – return to the controller main screen. It is not used
while selecting operation mode and burner startup, return to the
main screen is carried out automatically.
3.1 Burner startup
AIR BIO PID Controller is able to automatically control flame startup process
and shutdown process in pellet burners.
To begin flame startup process it is required to go to the controller main menu,
select menu item «Firing»,
and press the encoder button. The Controller will go
back to the main screen (Picture 4), and “Firing/Flameup”,
operation mode icon will
pop up in the upper part of the screen. If the firing is successful the Controller moves to
the operating mode and starts implementing the task on temperature selection.
icon
will pop up on the screen.
The Controller carries out three attempts of firing, if it fails, there will be a
message about an error on the screen being accompanied by sound alarm.
3.2 Shutdown
This function is intended to stop burner operation. This process takes different
amounts of time (see item 5.4 «Flameout time»).
To begin the shutdown process it is required to press encoder button, main menu will
open, by turning encoder select menu item «Flameout»,
and press the encoder
button. The Controller will go back to the main screen, and “Flameout”
operation
mode icon will pop up in the upper part of the screen.
3.3 PID Mode Setting Up
The boiler operation parameters during the fuel combustion process are set up in
this menu. The following items are included:
Internal screw – operation time for the internal screw is set
up.
Fuel Delivery – operation time and breaks of screw feeder
are set up.