background image

2

1. INTENDED 

USE

This liquid handling device is designed and manufactured to be 

used  with the IVD-product as an IVD-accessory and as a stand 

alone laboratory equipment.

2. PRODUCT 

DESCRIPTION

Your new Biohit 

m

LINE is an autoclavable air displacement 

pipette. The attractive and ergonomical design of the 

m

LINE 

pipette together with its very low pipetting forces reduce the risk 

of repetitive strain injuries (RSI)

1

. The pipette is designed for both 

right- and left-handeduse

The special tip cone design of the pipette offers the possibility to 

use replaceable Safe-Cone 

fi

 lters to help prevent the contamination 

and damage of the pipette. The operating button of the 

m

LINE 

allows safe and easy 

fi

 lter ejection. The pipette uses disposable 

tips.

Biohit

 

m

LINE single- and multichannel pipettes

 

1. 

Note:

 It is knowledge that prolonged pipetting can cause RSI. 

The manufacturer is not responsible for RSI or any related diseases 

caused by prolonged pipetting.

  

 

  

 

Safe 

Cone 

fi

 lters 

 

Colour  

 

Volume 

 

 

50 pcs/bag

Cat. No.  Code  Channels 

Range  

Increment  

Tip       Standard   Plus  

725010 

Grey 

1-ch 

0.1 - 3 

μ

l  

0.002 

μ

l 10  N/A N/A 

725020 

Grey 

1-ch 

0.5 - 10 

μ

l  

0.01 

μ

l  

10  

N/A  

N/A 

725030   Yellow  

1-ch 

2 - 20 

μ

l 0.02 

μ

l  

300  

721014 

N/A

725050   Yellow  

1-ch 

10 - 100 

μ

l 0.1 

μ

l  

300, 350   721008   721018

725060   Yellow  

1-ch 

20 - 200 

μ

l  

0.2 

μ

l  

300, 350   721007   721017 

725070  

Blue  

1-ch 

100 - 1000 

μ

l  

μ

l  

1000  

721006   721016 

725080   Green 

1-ch 

500 - 5000 

μ

l  

10 

μ

l  

5000 

721005   721015

725090 

Red 

1-ch 

1 - 10 ml 

20 

μ

l 10 

ml 

721005 

721015

725120  

Grey  

8-ch 

0.5 - 10 

μ

l   

0.01 

μ

l  

10  

N/A 

N/A

725130   Yellow  

8-ch 

5 - 100 

μ

l 0.1 

μ

l  

300, 350   721008   721018

725140  Orange   8-ch 

30 - 300 

μ

l  

0.2 

μ

l  

350  

721007   721017 

725220  

Grey  

12-ch 

0.5 - 10 

μ

l  

0.01 

μ

l  

10  

N/A  

N/A 

725230   Yellow 

12-ch 

5 - 100 

μ

l  

0.1

μ

l  

300, 350  721008   721018

725240   Orange  12-ch 

30 - 300 

μ

l  

0.2 

μ

l  

350 

721007  721017

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Содержание mLINE

Страница 1: ...t Service Center Repairs Experienced Engineers and Technicians on staff in our State of the art Full Service In House Service Center Facility InstraView Remote Inspection Remotely inspect equipment be...

Страница 2: ...mLINE Instruction Manual Bedienungsanleitung Mode d emploi Manual Usuario Instruzioni d impiego Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Страница 3: ...seal 7 Calibration nut cover 8 Display 9 Handle 10 Tip ejector 11 ID window 12 ID tag 13 Handle collar 14 Cap set of 5 colours Ersatzteile Spitzenabwurf Konusfilterhalter Spitzenkonus Konuszylinder K...

Страница 4: ...satzteile Spitzenkonus geh use Spitzenabwurfs balken Spitzenkonus Kolben Kolbenzu sammensetzung Abdeckung Kalibrierschraube Display Handgriff Spitzenabwerfer ID Fenster ID Aufkleber Griffhalter Abdeck...

Страница 5: ...anual 1 Bedienungsanleitung 17 Mode d emploi 33 Manual Usuario 49 Instruzioni d impiego 65 81 Specifications 97 mLINE Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan sc...

Страница 6: ...UES 7 9 1 Forward pipetting Fig 5 8 9 2 Reverse pipetting Fig 9 8 9 3 Repetitive reverse technique 9 10 RECOMMENDATIONS FOR GOOD PIPETTING 9 11 MAINTENANCE 9 11 1 Daily cleaning of the outer surface o...

Страница 7: ...pipetting can cause RSI The manufacturer is not responsible for RSI or any related diseases caused by prolonged pipetting Safe Cone filters Colour Volume 50 pcs bag Cat No Code Channels Range Incremen...

Страница 8: ...ck Colour coding Tip ejector collar Tip cone ID window and tag Finger support Handle Calibration nut Safe Cone filter Tip cone Tip cone housing Tip ejector bar Safe Cone filter Artisan Scientific Qual...

Страница 9: ...alibration tool also tube and ID window opener 5 Pipette holder 6 Identification tags 7 Safe Cone filters pipettors 10 l 8 Grease 9 Instruction manual 10 Performance certification in accordance with I...

Страница 10: ...stall the holder by pressing it against the edge of the shelf Fig 2 4 Place the pipette onto the holder 6 2 Carousel stand A convenient and ergonomical Carousel Stand Fig 3 for six Biohit mLINE pipett...

Страница 11: ...lume range of the pipette Chapter 1 8 2 Sealing and ejecting tips To ensure the maximum accuracy and precision Biohit tips are recommended to be used with mLINE pipettes Before fitting a tip ensure th...

Страница 12: ...lter ejector without touching the filters by hand Remove the operating button cap and eject the filter by pressing the operating button down Fig 7 Make sure that the filter is disposed into a suitable...

Страница 13: ...p Fig 8 0 1 2 9 2 Reverse pipetting Fig 9 1 Fit the tip onto the pipette tip cone 2 Press the operating button all the way to the second stop 3 Place the tip just under the surface of the liquid 2 3 m...

Страница 14: ...tte on its side especially with the tip attached Change the tip cone filter regularly recommendation after 50 250 pipetting cycles Never strike the tip cone against the tip tray when mounting the tip...

Страница 15: ...the tip ejector collar 1 counterclockwise and remove it 3 Pipettes m3 m10 m20 m100 m200 m1000 Unscrew the tip cone holder 2 counterclockwise and carefully remove it with the tip cone 3 Pipettes m5000...

Страница 16: ...ase has spread evenly 5 Check the performance of the pipette Note It is always necessary to check the performance of the pipette after in house service or maintenance 11 3 Sterilization of the pipette...

Страница 17: ...fit the tip onto the tip cone 3 Fill the tip with test water and expel to waste five times to reach a humidity equilibrium in the dead air volume 4 Replace the tip Pre wet the tip by filling it once...

Страница 18: ...e and the selected test volume Random error imprecision is the scatter of the dispensed volumes around the mean of the dispensed volume ISO 8655 1 Note Biohit specifications are achieved in strictly c...

Страница 19: ...d of the calibration nut located at the backside of the handle with the aid of the calibration tool Fig 11 2 Place the hexagonal head of the calibration tool into the hole of the calibration nut 3 Tur...

Страница 20: ...r servicing Pipette out of Incorrect operation Follow instructions established specifications Unsuitable tip Use original tips Calibration altered Recalibrate Operating button Liquid has penetrated Cl...

Страница 21: ...OUTSIDE THEIR SPECIFICATIONS CONTRARY TO THE INSTRUCTIONS GIVEN IN THIS MANUAL OR WITH OTHER THAN THE MANUFACTURER S ORIGINAL TIPS Each Biohit mLINE pipette is tested before shipping by the manufactur...

Страница 22: ...l 1000 l 0 60 0 20 500 l 0 60 0 20 100 l 1 00 0 40 725080 1 500 5000 l 5000 l 0 50 0 20 2500 l 0 60 0 30 500 l 2 00 0 60 725090 1 1 10 ml 10 000 l 0 6 0 2 5000 l 1 2 0 3 1000 l 3 0 0 6 725120 8 0 5 10...

Страница 23: ...it gr ter Sorgfalt zusammengetragen Biohit ist nicht verantwortlich f r Fehler oder Auslassungen und beh lt sich das Recht vor nderungen ohne Ank ndigung vorzunehmen Alle Marken sind Eigentum von Bioh...

Страница 24: ...t Service Center Repairs Experienced Engineers and Technicians on staff in our State of the art Full Service In House Service Center Facility InstraView Remote Inspection Remotely inspect equipment be...

Отзывы: