ASSURANCE

 

GDS®

 

PPMX

 

USER

 

MANUAL

 

Technical

 

Specifications

 

Please

 

be

 

aware

 

of

 

the

 

following

 

before

 

operating

 

the

 

PPMX.

 

 

Changes

 

or

 

modifications

 

to

 

this

 

device

 

not

 

expressly

 

approved

 

by

 

BioControl

 

Systems

 

could

 

void

 

the

 

warranty.

 

 

The

 

instrument

 

complies

 

with

 

part

 

15

 

of

 

the

 

FCC

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

This

 

instrument

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

instrument

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

 

Shielded

 

cables

 

must

 

be

 

used

 

with

 

the

 

instrument

 

to

 

ensure

 

compliance

 

with

 

the

 

FCC

 

Class

 

A

 

limits.

 

 

Technical

 

Specification

 

Definition

 

Communications

 

USB

 

 

Connections

 

Three

 

USB

 

host

 

ports

 

and

 

one

 

USB

 

device

 

port

 

Two

 

inputs

 

(contact

 

closure,

 

TTL),

 

two

 

relay

 

outputs,

 

and

 

one

 

switched

 

+12V

 

DC

 

1A

 

output

 

NOTICE:

 

Switching

 

voltages

 

higher

 

than

 

30V

 

or

 

greater

 

than

 

1A

 

of

 

current

 

may

 

damage

 

the

 

instrument.

 

 

Dimensions

 

&

 

Weight

 

W

 

54.4

 

X

 

D

 

65.5

 

X

 

H

 

53.1

 

cm

 

(21.4

 

X

 

25.8

 

X

 

20.9

 

in),

 

24.9

 

kg

 

(55

 

lbs.)

 

 

Environmental

 

Conditions

 

Indoor

 

use

 

Altitude:

 

up

 

to

 

2000

 

m

 

Temperature

 

range:

 

5

 

°C

 

 

40

 

°C

 

Humidity:

 

Maximum

 

relative

 

humidity

 

80%

 

for

 

temperatures

 

up

 

to

 

31

 

°C,

 

decreasing

 

linearity

 

to

 

50%

 

relative

 

humidity

 

at

 

40

 

°C

 

 

Power

 

Requirements

 

External

 

Power

 

Supply

 

Voltage

 

Input

 

Frequency:

 

50

 

to

 

60

 

Hz

 

Voltage:

 

100

 

 

240V

 

AC

 

Voltage

 

Output

 

Voltage:

 

24V

 

DC

 

Current

 

Rating:

 

6.25A,

 

150W

 

 

Front

 

Panel

 

&

 

Control

 

 

Two

 

USB

 

host

 

ports

 

and

 

STOP

 

button,

 

Touchscreen

 

tablet

 

or

 

laptop

 

XYZ

 

Motion

 

(Speed)

 

1

500

 

mm/sec

 

in

 

X

 

dimension

 

1

550

 

mm/sec

 

(350mm/sec

 

default)

 

in

 

Y

 

dimension

 

(tray)

 

1

140

 

m/sec

 

in

 

Z

 

dimension

 

 

IMS

 

Head

 

  

PickPen

 

magnetic

 

head

  

 

IMS

 

Tips

 

 

PickPen

 

tip

 

covers

 

 

Liquid

 

Contact

 

Materials

 

 

Tips

 

 

100%

 

Virgin

 

Polypropylene

 

Tip

 

Disposal

 

Bin

 

 

Polypropylene

 

with

 

colorant

 

(Pro

fax

 

6523)

 

Liquid

 

Handling

 

Head

 

&

 

Tips

 

MAX8x200,

 

DIAMOND

 

filter

 

tips

 

(DF200)

 

 

Removable

 

Tray

 

Capacity

 

 

9

position

 

Safety

 

&

 

Compliance

 

Certified

 

to

 

safety

 

standards

 

specified

 

for

 

Canada,

 

Europe

 

and

 

the

 

United

 

States.

 

Refer

 

to

 

the

 

instrument

 

rear

 

panel

 

label

 

and

 

the

 

Declaration

 

of

 

Conformity

 

document

 

for

 

the

 

current

 

standards

 

to

 

which

 

the

 

instrument

 

has

 

been

 

found

 

compliant.

 

 

Содержание Assurance GDS PPMX

Страница 1: ...55240 R003 082016 ASSURANCE GDS PPMX USER MANUAL 12822 SE 32nd Street Bellevue WA USA 98005 Phone 425 603 1123 Fax 425 603 0070 info biocontrolsys com www biocontrolsys com...

Страница 2: ...nt Documentation Protocols Disposables Technical Specifications III Setup Operation 9 Unpacking Removable Tray Rear Panel Connections Front Panel Connections UPS Battery Power and Line Conditioner Pow...

Страница 3: ...tocol after Communication Loss Hood Open Reporting an Error Technical Services V Maintenance 25 Cleaning Pipette Head Calibration Alignment Calibration Preventative Maintenance Warranty Instrument Ret...

Страница 4: ...ASSURANCE GDS PPMX USER MANUAL 3 Best Practices XII Appendix G 35 Pack Up XIII Appendix H 39 Ordering Information...

Страница 5: ...fety standards of design manufacture and intended use of the instrument BioControl Systems assumes no liability for the customer s failure to comply with these requirements The PPMX has been certified...

Страница 6: ...ntainer The tip waste container should be emptied in accordance with national and local safety regulations Tray The moving tray is capable of causing injury by pinching For an instrument with the rota...

Страница 7: ...This user manual is intended to assist PPMX users with system start up basic operation maintenance and service Standard Equipment After the PPMX and accessories are unpacked the following items shoul...

Страница 8: ...son Installation and Operational Qualification IQ OQ Procedures Gilson Declaration of Conformity Gilson Validation Certificate for TRILUTION micro Gilson Quality Control Report Pipette Head Protocols...

Страница 9: ...3 1 cm 21 4 X 25 8 X 20 9 in 24 9 kg 55 lbs Environmental Conditions Indoor use Altitude up to 2000 m Temperature range 5 C 40 C Humidity Maximum relative humidity 80 for temperatures up to 31 C decre...

Страница 10: ...a 9 16 wrench if needed Lift straight up using handles on both sides 2 Remove the two grey foam pieces 3 Remove the closed and open ended cardboard accessories boxes by sliding them out from the bunge...

Страница 11: ...tray onto the metal carrier It is keyed and will only mount one way Observe that the tray is level and fully seated on the metal carrier Rear Panel Connections Refer to the diagrams on the next page...

Страница 12: ...RS 232 and HDMI are not supported 1 Input Output Green 2 USB host Not Supported 3 USB host 4 Ethernet Not Supported 5 USB device 6 RS 232 Not Supported 7 HDMI Not Supported 8 Powerreceptacle 9 Power...

Страница 13: ...quipment Power On and Start Up To start the PPMX 1 Make sure that the PPMX is connected to the external power supply and that the external power supply is connected to a power source 2 Turn power on a...

Страница 14: ...r the user The full name can be from 1 to 100 characters in length must begin with an English letter or number and may contain the following special characters _ and Spaces are valid 3 Optionally ente...

Страница 15: ...between the PPMX and control tablet if the battery runs too low Refer to the table below for a description of the icons used in the on screen keyboard The following icons appear on several screens in...

Страница 16: ...fere with the alignment Ensure that the clips are positioned as shown in the diagram below and that the thumbscrews have been tightened 4 Close the rotating cover 5 The tablet starts TRILUTION micro a...

Страница 17: ...l heads When finished adding heads select Back Set Date Time Set the date and time to ensure a correct date time stamp on protocol runs This should only have to be done once On the Settings menu selec...

Страница 18: ...ecks that the PPMX is connected If connected the software goes to the next screen If not connected a message will appear suggesting possible solutions 5 Enter sample number kit and reagent information...

Страница 19: ...ew for each clip 2 Place the tip rack on the removable tray with the beveled corner in the back left corner 3 Rotate each clip so that it will effectively secure the tip rack on the tray as shown in t...

Страница 20: ...with the slide bar on the left side Slice the amp tubes and expand the plate prior to adding the lid 15 If individual sample IDs need to be entered for each sample in the sample block this can be don...

Страница 21: ...en The colors indicate the following information Red Negative volume Green Volume in the tube or well Blue Empty tube or well Pink Tips 6 The top of the screen shows the status the name of the protoco...

Страница 22: ...inganetwork enabled laptop ToimportdatafromaLIMSsystem thefollowingsteps shouldbefollowed 1 SelectStartutility 2 SelectLIMSAssistant 3 SelectIMPORT 4 Browseto selecttheLIMSimportfileforthePPMXprotocol...

Страница 23: ...ct Export 5 Browse for and select the destination USB drive for the protocol file and then select Open The protocol is saved to the location with a SQLITE extension Delete Protocol To delete a protoco...

Страница 24: ...the PPMX 7 Power the PPMX on first 8 Power the computer on 9 Proceed with selecting Run a protocol to check communication has been re established Re starting a Protocol after Communication Loss If dur...

Страница 25: ...portant for Technical Services to be able to adequately diagnose the issue 2 From the error message select Manual control 3 Check the box Home in recovery mode and select Home XYZ 4 Pipette should ret...

Страница 26: ...g Block s HT Amp Tube Block and Lid if applicable should be cleaned by lightly spraying a paper towel with 10 bleach solution and wiping the outside surface Follow with 70 isopropyl alcohol as describ...

Страница 27: ...r 10 Re alignment of system Contact BioControl Systems Technical Services at 425 603 1123 or techservices biocontrolsys com to schedule To help us serve you quickly and efficiently please refer to App...

Страница 28: ...PWR AND USB CABLING KIT 79121 BLACK PLUG FOR BACK COVER 79131 ALLEN WRENCH 5 MM 79101 REMOVABLE TRAY 96 WELL 79105 PIPETTE TIP RELOAD RACK 79173 PICKPEN TIP RELOAD RACK 79109 TIP DISPOSAL BIN 79103 AS...

Страница 29: ...REAGENT RESERVOIR CASE OF 25 79119 1 COLUMN REAGENT RESERVOIR CASE OF 25 73087 ASSURANCE GDS PICKPEN II TIPS RACKED 73085 ASSURANCE GDS PICKPEN II TIPS BULK 73004 ADHESIVE FILM SHEETS BOX OF 100 7302...

Страница 30: ...he PickPen magnetic head is located on the back outside casing o The serial number for the control tablet is located on the outside of the box o The serial number for the Surface laptop is located beh...

Страница 31: ...ASSURANCE GDS PPMX USER MANUAL 30 Appendix C Maintenance Log...

Страница 32: ...tion and testing BioControl shall repair or replace within 5 days of receipt by BioControl any such equipment found to be defective and promptly return such equipment to Buyer transportation and insur...

Страница 33: ...rompt 11 When run is completed weigh both filled GDS Sample Bases and the filled GDS Resuspension Plate and record weight NOTE The protocol will fill the CR and Resuspension Buffer 5x the standard amo...

Страница 34: ...ps 200 L filter 3 Reagent reservoir a Wash b c Empty d RS Buffer 4 Sample block 1 1 48 CR 5 Empty 6 Sample block 3 1 48 Wash 7 Reagent holder a Std or b HT CR bottle 8 RS plate 1 1 48 RS Buffer skippe...

Страница 35: ...3 is for sterile media BHI or DFB o Column 4 is for Resuspension Buffer Tq Re cap Concentration Reagent bottles after each run to prevent evaporative loss and store under refrigeration Cover reservoir...

Страница 36: ...d box and put into the accessories box 5 Place all the deck accessories into their respective plastic bags and place into the accessories box a Trash bin tip reload racks tip puck reagent holder and p...

Страница 37: ...n the base and press the white foam block into the opening to prevent the sheet from moving during shipping 11 Tape the Alignment Head cable to the foam block 12 Install the shipping bracket to the ar...

Страница 38: ...down when lifting PPMX to prevent damage from the lid crashing forward 16 Rotate the clear cover open until it catches on the magnets using lab tape secure tbe lower cover to the upper cover 17 Place...

Страница 39: ...or additional protection 22 Gently lower the crate lid over the PPMX unit being careful not to loosen the grey foam pieces This step requires 2 people 23 Attach the 4 bolts to the bottom of the crate...

Страница 40: ...or Listeria spp Tq The following kits are sold separately but are required for the ATM kit Wash Solution Part No Description 61031 100 GDS Wash Kit 4 x 250 mL RS Buffer Part No Description 34724 100C...