Section 7 Accessories and Replacement Parts 

 

7.1 Accessories 

 

Part number  Description 
100-1359 

Knob Knurled Head M6 (4) 

100-1361 

Lamp, UV B (302 nm – 1 each for Gel/ChemiDoc/XRS) 

100-1370 

UV TR Starter St151 (3 each) 

100-1381 

Lamp, Epi-illumination, 11 W PI1182 

100-1397 

UV Transilluminator Lid (Includes filter glass) 

100-1399 

Universal Hood Right Shield Epi-illumination 

100-1948 

Universal Hood Opal Filter Epi-illumination 

100-1949 

Universal Hood Left Shield Epi-illumination 

100-1950 

Universal Hood Screw Feet (4) 

100-1951 

Fuse T 2 A – 250 V (10 each)  

100-1952 

Fuse T 4 A – 250 V (10 each)  

100-2648 

Power Supply, Camera, ChemiDoc XRS 

100-2649 

Cable, Controller, ChemiDoc XRS 

100-2651 

Card, PCI Digitizing, ChemiDoc XRS 

170-3759 

Bio-Rad fluorescent Ruler 

170-3760 

Gel Cutter Ruler 

170-6887 

Kit, 6 lamp, 365 nm, Gel Doc 2000/ChemiDoc/ChemiDoc XRS 

170-7251 

Mitsubishi P-91W Printer 100 – 240 Volts 

170-7540 

Card, PCI Digitizing, Gel Doc 2000/ChemiDoc, CCIR 

170-7541 

Card, PCI Digitizing, Gel Doc 2000/ChemiDoc, RS170 

170-7546 

Cable, Integration controller Gel Doc 2000/ChemiDoc 

170-7582 

Mitsubishi K65H Paper, 4 rolls 

170-7813 

Sample Holders for gels 

170-7940  

UV/White Light conversion Screen,  

170-7950 

White Light Transilluminator upgrade for Universal Hood 

170-7951 

Camera, Gel Doc 2000, W/MZL, 115VAC 

170-7952 

Camera, Gel Doc 2000, W/MZL, 230VAC 

170-7953 

Camera, ChemiDoc , W/MZL, 115VAC 

170-7954 

Camera, ChemiDoc , W/MZL,  230VAC 

170-7959 

Converter, USB to MAC Serial (Includes USB Cable) 

170-7960 

Converter, USB-RS232 (PC) 

170-7961 

Kit, Filter, 58mm, Gel Doc 2000/ChemiDoc 

170-7962 

Shield, UV, Universal Hood 

170-7963 

Cable, Serial, MAC 

170-7964 

Cable, Serial, PC 

170-8008 

Fluorescent Reference Plate (ChemiDoc XRS only) 

170-8072 

Lens,f/0.95, 25mm, wide angle lens (ChemiDocXRS only) 

170-8073 

Lens,f/0.95, 17mm, wide angle lens (ChemiDocXRS only) 

170-8074 Filter, 

520DR30 

170-8075 Filter, 

560DF50 

170-8076 Filter, 

630BP30 

Page 31 of 42 

Содержание Gel Doc 2000ChemiDocChemiDoc XRS

Страница 1: ...Gel Doc 2000 ChemiDoc ChemiDoc XRS Hardware Instruction Manual Includes Universal Hood Catalog Number 170 8126 P N MI1708126AA Rev C...

Страница 2: ...versal Hood is warranted against defects in materials and workmanship for 1 year If any defect occurs in the instrument during this warranty period Bio Rad laboratories will repair or replace the defe...

Страница 3: ...strument not performed by Bio Rad Laboratories or an authorized agent Richtlinien WICHTIG Dieses Geraet von Bio Rad Laboratories konstruiert besitzt das Zertifikat ENC1010 anerkannt von dem internatio...

Страница 4: ...ights immediately after use Clean the transilluminator platen after use Generelle Vorsichtsmassnahmen Bitte die Bedienungsanleitung aufmerksam lesen Das Geraet darf nur fuer die vorgesehenen Applikati...

Страница 5: ...3 DESCRIPTION OF FUNCTIONS AND SYSTEM INITIALIZATION 19 4 3 1 Control panel 19 4 3 2 Initial test 22 4 3 3 Aligning the camera and bracket This applies to all systems 24 SECTION 5 OPERATION OF THE UNI...

Страница 6: ...for using the program is mainly determined by the size of the images you will scan and analyze Images scanned at high resolution can be quite large For this reason we recommend that you archive image...

Страница 7: ...gszwecke geeignet Ausserdem ist die Benutzung nur fuer spezialisiertes Personal gedacht das mit den Gesundheitsrisiken vertraut ist die an die UV Strahlung gebunden sind und den Reagentien die normale...

Страница 8: ...an optional UV White light conversion screen 170 7940 or White light transilluminator 170 7950 are available 3 3 PCI Digitizing Card The systems require a PCI Digitizing Card to convert the video sig...

Страница 9: ...ual Power cable 170 7541 7540 PCI Digitizing card RS170 CCIR 170 7546 Integrating Cable 170 8120 Gel Chemi Accessory Kit includes Focusing Target UV Ruler Gel Cutter Amber filter and filter adapter ri...

Страница 10: ...female end of power cable to the cabinet The power entry module is on the left side back of the cabinet Note Please do not connect the other end of power cable to a power source until all connections...

Страница 11: ...ck gasket and fix the bracket with the four washers and knobs e A completely assembled camera will look like the photo shown below Gel Doc CCD Camera assembled on the bracket Black plastic screw requi...

Страница 12: ...s of a Cable Power supply Camera Assembly with Motorized Zoom lens and 1 diopter assembled to it and a PCI digitizing card c Hold the camera so that the tripod mount is facing away from your hand see...

Страница 13: ...mbscrew and tightly secure the black adapter plate to the bracket i The lens body should be completely flush against the rubber gasket ii The lens should appear centered in the black adapter plate as...

Страница 14: ...een from inside the hood Center the lens in the opening of the hood as viewed from inside of the hood l Secure the bracket to the hood at to the four studs located on top of the hood by using four bla...

Страница 15: ...ng the PCI Card into the PC The drivers for this card need to be installed during the software installation Please refer to Appendix D regarding driver installation a Make sure that your computer is t...

Страница 16: ...iversal Hood Serial port DB25 on the back left side to the COM1 of the PC The PC MAC cable is included NOTE In case when a MAC has a USB port instead of the Serial Port use a USB to Serial Adapter 170...

Страница 17: ...hood and camera 2 Disconnect the camera and lens cables 3 Remove the ChemiDoc XRS camera from the bracket 4 Remove the existing Motorized Zoom Lens from the camera by turning the lens counterclockwise...

Страница 18: ...washer Make sure that the lens is seated properly in round slot in the soft side of the foam 8 Tighten the screw so that the camera is secured properly to the bracket Now place the Bracket Camera asse...

Страница 19: ...following section to become familiarized with each function Imaging Indicator LED Power Indicator LED Prep UV LED and button Trans UV LED and button Hold LED and button Trans White LED and button Epi...

Страница 20: ...ully open The UV shield has to be used but glass or mask and gloves are recommended to block the UV radiations This option is not applicable to the door Wichtig Wer die Absicht hat Banden aus dem Gel...

Страница 21: ...the aperture button on Close decreases the amount of light coming into the sensor thereby making the image darker Pushing the aperture button on Open increases the amount of light coming into the sen...

Страница 22: ...the door Epi lights are on Tran UV LED blinks Press the Epi White key again Close the door Epi lights and LED are turned off Trans UV LED turns off Press the Trans UV key Trans UV LED turns on Open t...

Страница 23: ...d to close the iris and increase the integration time Test Procedure For ChemiDoc XRS systems Only NOTE The Operation Test for the ChemiDoc XRS system is different from the Gel Doc 2000 or ChemiDoc sy...

Страница 24: ...tails on Dark Reference Subtraction refer to the Software Manual 4 3 3 Aligning the camera and bracket This applies to all systems Centering the CCD camera on the lens hole of the Universal Hood shoul...

Страница 25: ...stay in the center of the image throughout the zoom range 9 Select Fast on the universal hood Click on or press Focus button to check that the lens is responding If not adjust the position of the lens...

Страница 26: ...version screen or white light transillumiator focusing is easily achieved if the Iris is slightly closed 5 1 3 Acquire an image 1 Press the appropriate light source for your sample 2 Select an integra...

Страница 27: ...urn ON the UV Transilluminator after removing the Sample To achieve good focus you may need to close the aperture till proper focus is achieved 11 Remove the sample from the Transilluminator Clean the...

Страница 28: ...V Trans LED stops blinking 2 Place the clear acrylic UV protection screen upright in the metal brackets on the front edge of the transilluminator CAUTION VORSICHT WARNING EXPOSURE TO UV RADIATION IS H...

Страница 29: ...just contrast brightness and gamma on the thermal printer Light leakage into the darkroom he rear hole on the MZL not closed with the screw The Lens body is not properly centered and against the light...

Страница 30: ...possible exposure Close the IRIS using the IRIS control until Auto expose is possible Unable to focus on the sample using White Light Transilluminator or conversion screen Aperture is open too wide c...

Страница 31: ...subishi P 91W Printer 100 240 Volts 170 7540 Card PCI Digitizing Gel Doc 2000 ChemiDoc CCIR 170 7541 Card PCI Digitizing Gel Doc 2000 ChemiDoc RS170 170 7546 Cable Integration controller Gel Doc 2000...

Страница 32: ...093 Upgrade kit CCIR MZL PC Gel Doc 2000 to ChemiDoc 170 8094 Upgrade kit RS170 MZL MAC Gel Doc 2000 to ChemiDoc 170 8095 Upgrade kit CCIR MZL MAC Gel Doc 2000 to ChemiDoc 170 8096 Lens Motorized 8 85...

Страница 33: ...old each lamp housing to the internal side of the hood Remove these nuts The cover screen with a plastic piece will come loose and the lamp will become visible To remove the lamp hold it from the rece...

Страница 34: ...hemical agents used as gel dyes Please use protective gloves when touching the UV transilluminator cover The lamps must be replaced after every 500 hours of use Turn off the power Remove the power cab...

Страница 35: ...trument Remove the lid Place it down on its backside on a non abrasive surface Caution Do not put the UV filter directly on the bench To replace the starter rotate it counter clockwise and remove To r...

Страница 36: ...r cable should be already plugged into the CCD camera 12 V AC DC connector e Connect each end of the CCD Camera cable following the instruction below Label Color Instrument Connection 9 pin connector...

Страница 37: ...d and attach it with the four washers and knobs d Connect each end of the CCD Camera cable following the instruction below Label Color Instrument Connection 9 pin connector Black PCI board Back of com...

Страница 38: ...Com1 port This option permits to b Connect the camera power cable to the connector on the camera labeled POWER See picture below Camera Power Supply Connector on the cable Power connector on the came...

Страница 39: ...the Universal Hood e In case of a MAC with a USB connect the optional 170 7959 USB to Serial adapter not included with a USB cable to the MAC and then connect the 8 pin round connector of the MAC ser...

Страница 40: ...the PC The following procedure describes how to install the drivers that are provided with your TDS Quantity CD ROM a Insert TDS Quantity One CD into the CD ROM drive of the PC It will go into AUTO RU...

Страница 41: ...is self installing utility will install the appropriate drivers on your PC f Next install the PCI Card into the PC The operating system will automatically find the card and appropriate driver and inst...

Страница 42: ...752 x 582 CCIR 768 H x 494 V RS170 752 x 585 CCIR 1300 x 1030 Pixel Size in Microns 8 4 H X 9 8 V 8 4 H X 9 8 V 6 7 H X 6 7 V Cooling System No 2 stage Peltier Peltier cooled Camera Cooling Temp NA 4...

Отзывы: