8
• Always disconnect the battery(s), or other 12v source, before installation or performing any maintenance.
• The ballast is supplied with a 6-foot, 2 wire, power cord and 5-foot lamp cord, the ballast must be located so the lamp is
easily removed and does not put any tension on the lamp, which could cause damage to the lamp and/or quartz sleeve.
All installed wiring should be protected from heat, wear points (abrading) or mechanical stress. Secure ballast using the
mounting tabs located on the ballast body.
• Wire ballast power cord as follows;
• Brown wire - Positive (+) to protected (fuse or circuit breaker) 12v DC source.
• Blue wire - Negative (-) to suitable chassis ground.
• If there are any questions or concerns regarding the installation and/or wiring of the 12v system, consult a qualified
installer.
8. It is recommended, when the carbon filter is new, to flush out the system thoroughly prior to use. Turn on the system’s faucet
and allow water to run for 10 minutes to flush the filter and system.
Figure 4 -
Bio-Logic
®
Pure Water Pack
TM
- Install
9. Plug ballast into an approved Ground Fault Circuit Interrupt (GFCI) receptacle. Where a 2-prong or unprotected 3-prong
receptacle is encountered, it must be replaced by a properly grounded Ground Fault Circuit Interrupt (GFCI) receptacle.
Installation must be in accordance with the National Electrical Code and any local codes and ordinances by a qualified
electrician.
10. Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing. This is done by
introducing chlorine or other disinfectant solution directly into the purifier chamber, a 100-ppm of chlorine is suggested. With
the disinfectant solution in the purifier chamber, turn the ultraviolet purifier on. Open the “downstream” outlet until order is
noticed. Close the outlet and allow the disinfectant to remain in the plumbing for at least three (3) hours. Flush the plumbing
with ultraviolet purified water; allow the water to run for several minutes before use, this will allow the ultraviolet lamp to
reach its full germicidal output.
Содержание PURE WATER PACK BIO 1.5 PWP
Страница 19: ...19 MAINTENANCE NOTES...