background image

15

b

allast

 n

o

. 10-0518a 

and

 10-0514a 

haVe

 l

amP

-

out

 P

roteCtion

 

If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast’s lamp-out protection 

will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. 

To reset: disconnect the 

ballast from power and reconnect or replace the lamp.

 The ballast must remain disconnected from power for (2) minutes to 

reset. After 2 minutes restore input power, ballast should resume proper operation.

  

The equipment that this ballast is used with requires connection to a known good ground. It is the User’s 

responsibility to ensure that their equipment is properly grounded in compliance with the National Electrical Code and any 

applicable local codes. Equipment wiring and hook up should be performed by a qualified, licensed electrician. Failure to comply 

with this requirement could result in serious injury or death.

TECHNICAL SPECIFICATIONS

Table 3 - Technical Specifications

Model:

Pure Water Pack

TM

Flow Rate (GPM):

1.5

Inlet\Outlet Size:

1/4” Tubing to 3/8” MNPT 

John Guest

TM

 Connector

Number of Lamps:

1

Lamp Model No.:

05-1366-R

Quartz Sleeve:

Yes

Length:

14 1/2”

Width:

5 3 /4”

Height:

18”

Shipping Weight:

18 Lbs

Voltage:



120V 50/60Hz

Power Consumption:

k

14 Watts

Max Operating Pressure:

100 PSI

Ambient Room Temperature:

35° F - 100° F

Lamp Out Indicator

Yes

Installation Kit

Yes

Sediment Filter Cartridge

Yes, 5 Micron

Carbon Filter Cartridge

Yes

Chamber Material

316 Stainless Steel

 

M

220v 50/60Hz and 12v DC  units are also available. Consult Factory for specific voltage requirements.

 

k

Wattage is lamp watts only, and does not include ballast loss.

All specifications, dimensional data, etc are approximate and subject to change without notice. 

  

12 Volt and 24 Volt Direct Current (DC) Ballasts and Units

Many individuals regard ballasts and units powered by 12 volt and 24 volt Direct Current (DC) to be 

relatively benign from a safety standpoint. However, a DC ballast, in order to operate an ultraviolet 

discharge lamp, must produce an output as high as 600 volts. This voltage is high enough to produce a 

very serious or even lethal electric shock. IT IS IMPERATIVE that all DC ballasts and DC ultraviolet 

units be wired and grounded appropriately.

Содержание PURE WATER PACK BIO 1.5 PWP

Страница 1: ...SA Models Ballast 120v 50 60 Hz Ballast 230v 50 60Hz BIO 1 5 PWP 10 0518A 10 0514A Extensive Product Information Available at ultraviolet com buyultraviolet com Installation Operation Maintenance Read...

Страница 2: ...ISTRATION 20 WARRANTY 20 Patent Notice 20 These instructions generally describe the installation operation and maintenance of the Bio Logic Pure Water PackTM Questions that are not specifically answer...

Страница 3: ...to determine and validate the suitability of this equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performanc...

Страница 4: ...osing it to the germicidal lamp Exposure time is related to the flow rate the higher the flow rate the lower the exposure time or the lower the flow rate the higher the exposure time The ultraviolet i...

Страница 5: ...ter purifier MUST be connected to the cold water line only 5 The system should be located as close to the faucet as possible This eliminates the possibility of the purified water being re contaminated...

Страница 6: ...til it is firmly seated The valve is CLOSED in this position 4 Open the cold water supply valve or main valve check for any signs of leaks around valve connection 5 Install John GuestTM Tubing Connect...

Страница 7: ...r b Run the precut 24 tubing from the outlet of the carbon filter to the inlet of the Bio Logic water purifier c Run the tubing from the faucet to the outlet of the Bio Logic water purifier Measure cu...

Страница 8: ...ter to run for 10 minutes to flush the filter and system Figure 4 Bio Logic Pure Water PackTM Install 9 Plug ballast into an approved Ground Fault Circuit Interrupt GFCI receptacle Where a 2 prong or...

Страница 9: ...let Corporation maintains a qualified team of application specialists that can provide any technical assistance which maybe required during the use of this system For any questions concerns or technic...

Страница 10: ...dal lamp operation This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission through the water 2 To ensure proper operation of the Bio Logi...

Страница 11: ...ir bubbles Turn off the faucet and check between the filter housing and head for leaks 12 It is recommended when installing a new carbon filter to allow the water to run for 10 minutes to flush the fi...

Страница 12: ...so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so...

Страница 13: ...Carefully discard all pieces of the broken quartz sleeve 8 Inspect the large O Ring used to seal the chamber and the chamber head Make sure the O Ring is seated properly between the chamber head ring...

Страница 14: ...power Verify that the purifier is connected to a live power source Water leaking from purifier Cracked or broken quartz sleeve Shut down purifier drain and replace quartz sleeve See Quartz Sleeve Ins...

Страница 15: ...Rate GPM 1 5 Inlet Outlet Size 1 4 Tubing to 3 8 MNPT John GuestTM Connector Number of Lamps 1 Lamp Model No 05 1366 R Quartz Sleeve Yes Length 14 1 2 Width 5 3 4 Height 18 Shipping Weight 18 Lbs Vol...

Страница 16: ...16 DIMENSIONAL DATA Figure 10 Dimensional Data All specifications dimensional data etc are approximate and subject to change without notice...

Страница 17: ...TM Ballast 12v DC 1 10 1201A 3 STER L RAY Lamp 1 05 1366 R 4 Static Gland Nut 2 25 1492D 5 Teflon Washer 2 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 1700A...

Страница 18: ...7 6 Screw 10 16 x Long 8 50 0096 7 Filter Cartridge 5 Micron Pleated 1 25 4508 8 Filter Cartridge Carbon 1 25 4509 9 Male Connector x3 8 NPTF John GuestTM 4 25 4513 10 Pipe Nipple 3 8 x1 Long PVC 1 25...

Страница 19: ...19 MAINTENANCE NOTES...

Страница 20: ...attempt has been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is...

Отзывы: