Cover for module slot 1
elmeg hybird 300
Functional earth strip of cover
elmeg hybird 300 earth bar
Lateral guide for modules
Arrows for open direction
Catch for cover at tachment
Detachable cover for RJ45 connectors of modules in slots 7 and 8
Detachable cover for terminal clamps of modules in slots 7 and 8
Connection screw for the earth bars
Fixation screws for the Connection module (These screws are provided with the modules.)
6.3.1 Opening the cover for module slot 1
(1)
When switched on, turn off power supply.
(2)
Remove screw (10).
(3)
Pull off cover in the direction of the arrow (6) and lift off upward. In this, be careful not to bend the brackets at
the ends of the earth bars (3) and (4).
6.3.2 Closing the cover for module slot 1
(1)
Insert the cover into the catches for fixation (7) and push back, opposite to the direction of arrow (6) while lightly
pressing the catches. Avoid bending the brackets on the earth bars.
(2)
Insert screw (10) and firmly tighten.
(3)
Restore power supply.
Achtung
The cover's earth bar must always be screwed together with the earth bar of the elmeg hybird 300.
Only this will create a continuous functional earth connection!
bintec elmeg GmbH
6 Mounting modules in the elmeg hybird 300
elmeg hybird 300 / 600