3.7 Contacts (switch contacts)
The elmeg hybird 300 / elmeg hybird 600 is equipped with two indepentend switch contacts. They can be used as
on-off switch or momentary switch. The electric circuit is opened, closed or closed for a specific time.
These functions are controlled by entering key numbers in conected phones.
The switching time for the momentary switch can be set in the GUI.
1
Switching voltage 10-13 V, max. 70 mA
2
Ground
3
Switch contact 2
4
Switch contact 1
5
Switch contact 1
6
Switch contact 2
7
-
8
-
Hinweis
The switch contacts offer a switching capacity of 0.5A at <60V CD or 1.0A at <30V DC.
3.8 Option
No function is currently assigned to this interface!
3.9 ETH1 - ETH5
5 Ethernet interfaces
An Ethernet interface is a physical interface for connection to the local network or external networks.
Ethernet ports ETH1 to ETH4 are assigned to a single logical Ethernet interface in the ex works state.
Port ETH5 is assigned to logical Ethernet interface en1-4 and is not preconfigured.
To ensure your device can be reached, when splitting ports make sure that Ethernet interface en1-0 with the precon-
figured IP address and netmask is assigned to a port that can be reached via Ethernet. If in doubt, perform the confi-
guration using a serial connection via the Serial 1 interface.