LEVEL APPLICATION EXAMPLE
The application is a vessel that takes an average 3 hours (180 minutes) to fill and 3 weeks to empty.
Fill rate = 0.08 m/minute [(Low Cal Pt. minus High Cal Pt)/fastest of fill or empty time]
= (15.5 m - 1 m) / 180 min.
= 14.5 m / 180 min.
= 0.08 m/min
Therefore SLOW response rate (0.1 m/min) can be selected.
Quick Start Parameter
Setting
Description
Vessel
STEEL
Selects vessel construction material.
Response Rate
SLOW
Resets Fill Rate/ Empty Rate to 0.1 m/minute.
Units
M
Sensor measurement units.
Operation
LEVEL (1)
Material level referenced from Low Cal. Point.
Low Calibration Point
15.5
Process empty level.
High Calibration Point
1.0
Process full level.
15.5 m
Low Calibration Point
Sensor Reference Point
Level
High Calibration
Point
1.0 m