10
ATTENTION!
Before connecting your equipment, always check that the mains voltage is the same as the
voltage of the equipment. If it is not the same, contact the manufacturer or your authorized
dealer.
The supply voltage of the devices is 110 V (60 Hz) or 220 V (50 or 60 Hz) single phase and
220 V or 380 V (50 or 60 Hz) three phase (PCL.98) as shown on the voltage label attached to
the power cable or as indicated on the card data label on the back of the unit (see the figure
on this label in item 2.2 of this manual).
Make sure that the voltage of the mains where the equipment will be installed is compatible
with the voltage indicated on these labels.
For details of the remainder of the electrical part of the equipment, refer to the wiring
diagram in the manual annexes.
IMPORTANT
The manufacturer shall not be liable for any direct or indirect damages caused by non-
compliance with these standards and other instructions presented in this manual.
3.3 Safety Measures and User Instruction
The professional that makes the sale of the equipment should instruct the user about the
correct operation of the equipment and should give you this instruction manual.
The user must be informed of the necessary safety measures and must respect them as well
as all the measures described in this manual.
Your equipment has mechanical guard (see item 1.2 Mechanical Safety). Removal or
tampering with these safety components can cause serious risks to the operator's upper limbs.
ATTENTION!
It is very important, before operating your equipment, to check the direction of rotation of
the endless spool or the cross blade. To do this, position yourself in front of the device and
looking at the power nozzle you can see the spool or if you look at the disc you will see the
crosspiece. Turn the unit on and turn it off quickly, leaving only the time required to check
the direction of rotation: the spool or crosspiece must be rotating counterclockwise
(pictured below), according to the direction indicated on the adhesive glued on the front the
case.
For your safety, always check the direction of rotation with the spindle nozzle mounted on
the bearing.