11.7.4 Terminal Tests/Terminal Configuration Report
If a printer port has been enabled through the relative menu, the terminal
configuration report will be printed via this port. If no port has been
enabled, connect a printer and a PC to the COM1 serial port with fixed
9600,8,N,1 configuration.
The overall setup of the terminal will be transmitted to it.
11.7.5 Terminal Tests/Analogue output
To calibrate the output voltage, connect a tester with 10V capacity to the
terminals. Adjust the output using the keys indicated on the display to
obtain a voltage reading between 0 and 10V.
To calibrate the output current, proceed in the same way using an
ammeter.
You can also select the
Complete calibr.
item of the menu to
calibrate both values (current and voltage)..
11.7.6 Terminal Tests/Battery
Indicates the voltage of the internal lithium battery.