![Bilanciai D450 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/bilanciai/d450/d450_user-manual_2750963022.webp)
When a bit assumes the value "1" the corresponding signal is "true"; the
significance of the signals is as follows:
<s1>
bit 0
minimum weighment signal
bit 1
tare locked signal
bit 2
tare preset(1)/self-weighed (0) entered signal
bit 3
centre zero signal
<s2>
bit 0
LSB weighing extension signal (ME only)
bit 1
weight stable signal
bit 2
overload signal
bit 3
MSB weighing extension signal (ME only)
<s3>
bit 0
tare entered signal
bit 1
tare locked cancelled signal (ME only)
bit 2
weight not valid
bit 3
printing in progress
<s4>
bit 0
approved instrument
bit 1
converter fault
bit 2
scale configuration parameters error
bit 3
not utilised