2016
www.B-TEK.com
Pit Type Truck Scale Installation Manual
5
Before Installation
Prior to installation verify the following:
• The scale design will meet the customer’s application correctly
• The scale is located so that vehicles can enter and exit easily
• There will be sufficient drainage of water from the scale area
• The approaches on both ends are level and meet the requirements of NIST Handbook 44, requiring that the
first 10’ is on the same plane of the platform
• Do not locate electrical components near any items with magnetic material. Additionally, do not locate
indicators in direct sunlight or in areas subject to extreme temperature changes as this may affect the accuracy
of the weighing.
• You have a copy of the scale and foundation drawings specific to this installation on site at the time of installation
• You have a copy of this manual on site at the time of installation
• The foundation concrete has had a full twenty-eight day period for proper curing
• All installation and calibration adjustments required for the scale to perform to its specified accuracy and
operation are considered to be part of the standard scale installation.
• Installations that cannot be finished in one session must ensure that proper signage and barriers are in place
to prevent use of the scale until fully operational
Содержание BTEK BS-FECD-P-CPD-M
Страница 1: ...BS FESD P CPR M BS FESD P CPD M BS FECD P CPR M BS FECD P CPD M Models Include ...
Страница 2: ...www B TEK com 2016 Pit Type Truck Scale Installation Manual 2 ...
Страница 22: ...www B TEK com 2016 Pit Type Truck Scale Installation Manual 22 See larger drawing in packet ...
Страница 23: ...2016 www B TEK com Pit Type Truck Scale Installation Manual 23 See larger drawing in packet ...