PAGE 4

T E C A L  4 2 5 S  O P E R A T O R ’ S   M A N U A L

Introduction

Please read all the information in this booklet before using
the unit.

Warning

HIGH TEMPERATURES ARE DANGEROUS: they can
cause serious burns to operators and ignite combustible
material.
Techne have taken great care in the design of these units
to protect operators from hazards, but users should pay
attention to the following points:

USE CARE AND WEAR PROTECTIVE GLOVES TO
PROTECT HANDS;

DO NOT put hot objects on or near combustible
objects;

DO NOT operate the unit close to inflammable liquids
or gases;

DO NOT place any liquid directly in your unit;

At all times USE COMMON SENSE.

Operator Safety

All users of Techne equipment must have available the
relevant literature needed to ensure their safety.
It is important that only suitably trained personnel operate
this equipment, in accordance with the instructions
contained in this manual and with general safety standards
and procedures.  If the equipment is used in a manner not
specified by Techne the protection provided by the
equipment to the user may be impaired.
All Techne units have been designed to conform to
international safety requirements and are fitted with an
overtemperature cutout.  On some models, the cutout is
adjustable and should be set to suit the application.  On all
other models the cutout is preset to protect the unit.
If a safety problem should be encountered, switch off at the
mains socket and remove the plug from the supply.

Installation

1.

All Techne units are supplied with a power cable.  This
may be integral or plug-in.

2.

Before connecting the mains supply, check the voltage
against the rating plate. Connect the mains cable to a
suitable plug according to the table below.  

Note that

the unit must be earthed to ensure proper electrical
safety.

Connections

220/240V

110/120V

Live

Brown

Black

Neutral

Blue

White

Earth

Green/yellow Green

The fused plug supplied with the mains lead for use in
the UK is fitted with the following value fuse to protect
the cable:

230V UK

10 AMP

The fuse in the unit protects the unit and the operator.
Note that units marked 230V on the rating plate work
at 220V; units marked 120V work at 110V.  In both
cases, however, the heating rate will degrade by
approximately 8%.  The rating plate is on the rear of the
unit.

3.

Plug the mains cable into the socket on the rear of the
unit.

4.

Place the unit on a suitable bench or flat workspace, or
in a fume cupboard if required, ensuring that the air
inlet vents on the underside are free from obstruction.

5.

Note that the following symbols may be next to the
indicator lamps on the front panel of the units and have
the following meanings:

: the power indicator

: the heater indicator

: the overtemperature indicator

6.

Symbols on or near the power switch of the unit have
the following meanings:

I

: mains switch On

O

: mains switch Off

After use

When you have finished heating samples, remember that
parts of the unit – the tubes, blocks and associated
accessories –  may be very hot. Take the precautions listed
earlier.

Guarantee

The unit is guaranteed against any defect in material or
workmanship for the period specified on the enclosed
guarantee card. This period is from the date of purchase,
and within this period all defective parts will be replaced
free of charge provided that the defect is not the result of
misuse, accident or negligence. Servicing under this
guarantee should be obtained from the supplier.
Notwithstanding the description and specification(s) of the
units contained in the Operator’s Manual, Techne hereby
reserves the right to make such changes as it sees fit to the
units or to any component of the units.
This Manual has been prepared solely for the convenience
of Techne customers and nothing in this Instruction Book
shall be taken as a warranty, condition or representation
concerning the description, merchantability, fitness for
purpose or otherwise of the units or components.

User maintenance

NOTE THAT THIS EQUIPMENT SHOULD ONLY BE
DISMANTLED BY PROPERLY TRAINED PERSONNEL.
REMOVING THE SIDE, FRONT OR REAR PANELS
EXPOSES POTENTIALLY LETHAL MAINS VOLTAGES.
THERE ARE NO USER MAINTAINABLE PARTS WITHIN
THE EQUIPMENT.
In the unlikely event that you experience any problems with
your unit which cannot easily be remedied, you should
contact your supplier and return the unit if necessary.
Please include any details of the fault observed and
remember to return the unit in its original packing.  Techne
accept no responsibility for damage to units which are not
properly packed for shipping: if in doubt, contact your
supplier.  See the Decontamination Certificate supplied
with your unit.

1. Cleaning

Before cleaning your unit ALWAYS disconnect from
the power supply and allow to cool below 50° C.
Your unit can be cleaned by wiping with a damp soapy
cloth.  Care should be exercised to prevent water from
running inside the unit.  Do not use abrasive cleaners.

2. Fuses

Your unit is protected by one or two fuses.  These
should only be changed by suitably qualified personnel.
If the fuses blow persistently, a serious  fault is indicated
and you may need to return the unit to your supplier for
repair.

Содержание TECHNE Tecal 425S

Страница 1: ...Tecal 425S Calibrator Operator s Manual Issue 5 Date of issue 3rd May 2005 Techne is a trademark Techne 2003...

Страница 2: ......

Страница 3: ...ions 8 Warning 8 Specification 9 Working Conditions 9 Packing 9 WHEN YOU SWITCH ON 10 Front Panel controls 10 Setting the Units for Temperature 12 Setting the Operating Temperature 12 Cooling Probe 13...

Страница 4: ...PAGE 2 T E C A L 4 2 5 S O P E R A T O R S M A N U A L...

Страница 5: ...PAGE 3 T E C A L 4 2 5 S O P E R A T O R S M A N U A L NOTES...

Страница 6: ...that the air inlet vents on the underside are free from obstruction 5 Note that the following symbols may be next to the indicator lamps on the front panel of the units and have the following meanings...

Страница 7: ...assurant que les trous d a ration situ s sous l appareil ne sont pas obstru s 5 Les symboles ci dessous situ s c t des t moins lumineux sur la face avant de l appareil ont la signification suivante t...

Страница 8: ...Entl ftungsrippen an der Ger teunterseite immer frei zug nglich sind 5 Wenn die Anzeigenl mpchen an der Vorderseite leuchten hat dies folgende Bedeutung Ger t ist eingeschaltet Ger t heizt bertemperat...

Страница 9: ...to a las luces indicadoras en el panel frontal del equipo tienen los siguientes significados Indicador de potencia Indicador del calor Indicador de sobretemperatura 6 Los s mbolos que se encuentran en...

Страница 10: ...tailed towards the back of this manual Maintaining a set temperature The required temperature is set on the calibrator and the operation of the probe is checked A UKAS certificate can be provided cont...

Страница 11: ...of inserts at the back of this book Depth 130mm 5 1 Diameter 38 2mm 1 5 Reference well Depth 101 6mm 4 Diameter 6 6mm 0 26 Working conditions The Tecal units are designed to work safely under the foll...

Страница 12: ...econd then the actual temperature of the block will be indicated The Front Panel Controls The front panel controls consist of three buttons for controlling the display a five digit LED display and thr...

Страница 13: ...ndicator shows that there is power to the unit Power to the Block Indicator The next indicator shows when there is power to the block When the set temperature is higher than the block temperature this...

Страница 14: ...ROW buttons at the same time To convert back press both buttons again Setting the Operating Temperature 1 To display the set temperature on the digital display press and hold the SET Temperature butto...

Страница 15: ...ive build up of moisture will occur which may cause damage to the interior of the unit After Use 1 When you have finished heating samples remember that parts of the unit inserts and associated accesso...

Страница 16: ...owered up otherwise data integrity cannot be guaranteed Once the cable is fitted it does not matter which unit is powered up first RS232 9 way PC serial port ON OFF switch Fuses Power inlet The follow...

Страница 17: ...ndent circuits to protect it from overheating The unit constantly checks that the block temperature does not exceed its maximum If for some reason this temperature is exceeded all power to the block i...

Страница 18: ...calibrator to your supplier for repair Never fit a fuse rated higher than the value indicated on the unit serious damage or personal injury may result Replacement parts Each unit is supplied with an...

Страница 19: ...ation Aluminium Inserts Immersion depth 114 3 mm or 4 5 NUMBER PROBE DIAMETER METRIC FINSALA 5 off 6mm FINSALB 1 off each 10mm 8mm 6mm 4 5mm 3mm FINSALC 2 off 6mm 2 off 10mm FINSALD 2 off 6mm 2 off 12...

Страница 20: ...PAGE 18 T E C A L 4 2 5 S O P E R A T O R S M A N U A L...

Страница 21: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Отзывы: