VISTA SW 260 SXL / VISTA SW 260 MXL -
29
D814148 2F
A00_01
ENGLISH
INSTALLATION MANUAL
PARAMETER
DEFINITION
MIN
MAX
DEFAULT
PERSONAL
DESCRIPTION
22
Master/Slave closing off set [s]
0
100
0
Master motor delay time during closing with respect to the slave motor. 100ms step
23
ESPE OPEN input polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
24
ESPE CLOSE input polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
25
KEY input polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
26
START 1 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
27
START 2 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
28
AUX IN1 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
29
AUX IN2 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
30
AUX OUT input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
31
Leaf Weight setting
0
3
0
0 = Automatic (detected during LP)
1 = Weight Level Low
2 = Weight Level Medium
3 = Weight Level High
32
Force level during Reset and
LP procedure
0
9
5
It regulates the motor force when the door is operated after a reset
(0 = minimum force, 9 = maximum force)
33
Opening Angle reduction
percentage level [%]
0
50
0
The opening angle, during normal operation, shall be reduced compared with the one detected
during the stop acquisition procedure, to allow operation in the absence of the mechanical stop
(adjustment step 1%)
34
Closing mode in non-Manual
mode
0
1
0
0 = Motor close-back
1 = Spring close-back
35
Disabled people opening
speed
0
1
0
0 = Low Energy
1 = speed as per parameters 1 and 2
36
Battery operation
0
2
0
0 = standard operation
1= continuous operation
2 = panic operation
37
START 2 input confi guration
1
2
0
0 = Operation as described at paragraph 21
1 = Disabled People opening : enabled in manual logic
2 = Disabled People opening: enabled in all logics
38
Type of switch logic selector
in use
For detailed information about
the connection please refer to
the specifi c documents
1
3
0
0 = Selector in header, normal logics
1 = 3-position rotary selector
2 = 4-position rotary selector
3 = Selector in header,Manual-Auto logics
39
Full closing speed
[°/s]
5
15
8
5°/s ÷ 15°/s (adjustment step 1°/s)
40
Partial opening percentage
level [%]
50
90
70
50% ÷ 90% (adjustment step 2%)
41
Anti-crushing during closing
with spring
0
1
0
0 = Motion Stop
1 = Motor re-opening
SD
Default setting for all
parameters and point reset
/
It restores all the parameters to the default values and resets the acquired path.
Procedure:
1- Select the command using the [+] and [-] buttons;
2- Press [ENT];
3- When [--] is displayed, press [ENT] again for 5 seconds to validate the operation;
4- When [--] disappears, release the [ENT] button
LP
Leaf parameter acquisition
/
Path acquisition.
Procedure:
1- Select the command using the [+] and [-] buttons;
2- Press [ENT];
3- When [--] is displayed, press [ENT] again for 5 seconds to validate the operation;
4- When [--] disappears, release the [ENT] button.
In
System information
Procedure:
1 - Select the command using the [+] and [-] buttons;
2 - Press [ENT];
3 - Select the parameter to be displayed using the [+] and [-] buttons;
4 - Press [ENT];
5 - Press [ESC] to return to the selection of the paramters to be used.