12) “DISPLAY” OPERATING PARAMETERS MANAGEMENT
The two 7-segment displays, along with the 4 buttons, allow you to manage all the main parameters and the advanced options, ensuring an optimum management of
the automation for the diff erent installation types.
To properly see the display set the JP2 jumper according to the leaf opening side, referring to the arrows shown in fi gure 17.
The programming procedure is the following:
- Select the parameter to be edited using the [
+
] or [
-
] buttons; at this stage the indication on the display is fi xed.
- Press the [
ENT
] button. The display shows the value currently recorded in the board. This indication is blinking.
- You can change its value using the [
+
] or [
-
] buttons – to confi rm the change press the [
ENT
] button; the display returns to the number associated with the edited parameter.
- Press the [
ESC
] button to exit the parameter editing mode.
Note
: a time-out is activated during the parameter selection/editing stage; if no buttons have been pressed for over 10 seconds the system exits the programming stage.
PARAMETER
DEFINITION
MIN
MAX
DEFAULT
PERSONAL
DESCRIPTION
01
Opening speed [°/s]
20
70
60
Motor speed during the opening stage (adjustment step 5°/s).
02
Closing speed [°/s]
10
40
20
Motor speed during the closing stage (adjustment step 5°/s).
03
Normal pause time [s]
0
60
0
Waiting time before automatic closing.
62: 2 min
63: 3 min
64: 4 min
04
Pause time for disabled
people [s]
5
60
5
Waiting time before automatic closing when the disabled people opening command is used or
in Low Energy mode (adjustment step 1s).
62: 2 min
63: 3 min
64: 4 min
05
VISTA SW 260 SXL:
Spring closing speed
1
9
5
Spring closing speed (1=minimum speed, 9=maximum speed).
VISTA SW 260 MXL:
Wind resistance with closed
door
0
9
0
It adjusts the wind resistance force with closed door
(0=wind resistance force disabled, 1=wind resistance force enables at minimum level, 9=wind
resistance force enabled at maximum level).
06
Opening Force and Closing
Force
1
9
5
Force exerted by the leaf during the opening and closing stage before an obstacle alarm is
generated. (1=more sensitive; 9=less sensitive).
07
Acceleration and Deceleration
5
30
30
Acceleration and deceleration speed (adjustment step 1).
08
Full closure angle
10
40
20
It adjusts the full closure angle (closing is 1/2 of opening).
09
Electric lock voltage
0
1
0
0 = 12V electric lock output
1 = 24V electric lock output
10
Electric lock type
0
6
0
0= not used
For information about the type of electric locks that can be used please refer to the paragraph
“ELECTRIC LOCK MANAGEMENT”.
11
Electric pulse management time
Opening delay after lock release
0
9
2
The time depends on the electric lock type:
see the “ELECTRIC LOCK MANAGEMENT” paragraph.
12
Electric lock closing force
0
9
5
Force exerted by the leaf to allow the lock coupling.
LOW ENERGY
The automation opens and closes at reduced speed. Set the opening and closing times according to the weights and to the door width,
referring to the table:
Leaf weight (kg)
50
60
70
80
90
L
eaf length
(mm)
750
3,0s
3,0s
3,0s
3,0s
3,5s
850
3,0s
3,0s
3,5s
3,5s
4,0s
1000
3,5s
3,5s
4,0s
4,0s
4,5s
1200
4,0s
4,5s
4,5s
5,0s
5,5s
The specifi ed times refer to the opening from 00 to 800 and to the closing from 900 to 100.
PUSH&GO
A manual displacement of the leaf from the closed position triggers an automatic opening and closing action
WARNING: each time you change the DIP setting, validate it by performing a RESET of the board, turning it off and then back on.
11.3) “LOW ENERGY” OPERATION
A door operating at “low” energy (not exceeding 1.69 J) shall be set up in such a way as to ensure that:
- The minimum leaf closing times (from 90° to 10°) are equal to or greater than the values listed in Table 1.
- The minimum leaf slow-down time during the closing stage (last 10°) shall be of at least 1.5 s.
- The force required to hold the leaf shall not exceed 67 N anywhere in the closing or opening motion range (applied to the main closing edge in the direction of
travel);
- In the case of power failure or motor failure, the leaf can be released with a force of less than 67N and can be opened with a force of no more than 90N (applied
to the main closing edge in the direction of travel).
Note: a static closing force as high as 150N is allowed anyway when the gap between the main closing edge and the ledge one is ≤8 mm.
Table 1 - Minimum leaf closing times.
Leaf width
(mm)
Leaf weight (kg)
50
60
70
80
90
750 mm
3.0 s
3.0 s
3.0 s
3.0 s
3.5 s
850 mm
3.0 s
3.0 s
3.5 s
3.5 s
4.0 s
1,000 mm
3.5 s
3.5 s
4.0 s
4.0 s
4.5 s
1,200 mm
4.0 s
4.5 s
4.5 s
5.0 s
5.5 s
To change the closing speed, please refer to paragraph 12.