background image

12

 -

 HYDRA-R - Ver. 05

D811425_05

INSTALLATION MANUAL

ENGLISH

Thank you for buying this product, our company is sure that you will be more 
than satisfied with its performance.
This product is supplied with an “Instruction Manual” which should be read 
carefully as it provides important information about safety, installation, ope-
ration and maintenance. 
This product complies with recognised technical standards and safety regula-
tions. We declare that it is in conformity with the following European Directives: 
89/336/EEC, 73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.

•   The “

Warnings

”  leaflet  and “

Instruction  booklet

”  supplied  with  this 

product should be read carefully as they provide important information 
about safety, installation, use and maintenance.

•   Scrap packing materials (plastic, cardboard, polystyrene etc) according 

to the provisions set out by current standards. Keep nylon or polystyrene 
bags out of children’s reach.

•   Keep  the  instructions  together  with  the  technical  brochure  for  future 

reference.

•   This  product  was  exclusively  designed  and  manufactured  for  the  use 

specified in the present documentation. Any other use not specified in 
this documentation could damage the product and be dangerous.

•   The Company declines all responsibility for any consequences resulting 

from  improper  use  of  the  product,  or  use  which  is  different  from  that 
expected and specified in the present documentation.

•   Do not install the product in explosive atmosphere.
•   The construction components of this product must comply with the following 

European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned 
standards as well as the current national standards should be respected 
in order to achieve a good safety level.

•   The Company declines all responsibility for any consequences resulting 

from failure to observe Good Technical Practice when constructing closing 
structures (door, gates etc.), as well as from any deformation which might 
occur during use.

•   The installation must comply with the provisions set out by the following 

European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent 
amendments.

•   Disconnect the electrical power supply before carrying out any work on 

the installation. Also disconnect any buffer batteries, if fitted.

•   Fit an omnipolar or magnetothermal switch on the mains power supply, 

having a contact opening distance equal to or greater than 3,5 mm.

•   Check that a differential switch with a 0.03A threshold is fitted just before 

the power supply mains.

•   Check that earthing is carried out correctly: connect all metal parts for 

closure (doors, gates etc.) and all system components provided with an 
earth terminal. 

•   Fit all the safety devices (photocells, electric edges etc.) which are needed 

to protect the area from any danger caused by squashing, conveying and 
shearing.

•   Position at least one luminous signal indication device (blinker) where it 

can be easily seen, and fix a Warning sign to the structure.

•   The Company declines all responsibility with respect to the automation safety 

and correct operation when other manufacturers’ components are used.

•   Only use original parts for any maintenance or repair operation.
•   Do not modify the automation components, unless explicitly authorised 

by the company.

•   Instruct  the  product  user  about  the  control  systems  provided  and  the 

manual opening operation in case of emergency.

•   Do not allow persons or children to remain in the automation operation area.
•   Keep  radio  control  or  other  control  devices  out  of  children’s  reach,  in 

order to avoid unintentional automation activation.

•   The user must avoid any attempt to carry out work or repair on the automa-

tion system, and always request the assistance of qualified personnel.

•   Anything which is not expressly provided for in the present instructions, 

is not allowed.

•  Installation must be carried out using the safety devices and controls 

prescribed by the EN 12978 Standard.

2)  GENERAL OUTLINE

The 

HYDRA-R

 control panel is suitable for controlling 1 or 2

 PHEBE

 series 

operators, designed to automate different types of overhead doors. 
The panel can be either
-   fitted on board the 

PHEBE

 series (fig. 1) or

-   wall-mounted (fig. 2), when to be used for the series having no control 

units on board (

PHEBE – SQ

 series). 

For automation of an overhead door with two motors, 2 configurations are 
possible:   

-   no. 1 

PHEBE 

 + no. 1 

PHEBE -SQ

-   no. 2 

PHEBE -SQ

 + no. 1 

HYDRA-R 

with panel, wall mounted.

This control panel is supplied by the manufacturer with standard function 
setting. Any modification must be set by means of the incorporated display 
programmer or by means of 

UNIPRO

. The control unit fully supports the 

EELINK

 protocol.

These  are  the  main  innovative  characteristics  of  the 

HYDRA-R

  control 

panel:
-  management of one or two 24 V

+ torque

-  management of on-board receiver according to the new type of radio-

transmitter cloning 

-  presetting for operation by means of local and centralised commands via wire.

3) TECHNICAL SPECIFICATIONS 

Power supply: .............................................................. 230V

~

±10% 50 Hz*

Mains/low voltage insulation: .......................................> 2M Ohm 500 V 
Working temperature:  ............................................................. -10 to +55°C
Dielectric strength: ........................mains/low voltage 3750 V~ per 1 minute
Maximum power: ............................................................... 80W (2 PHEBE)
Blinker: ................................................................................ 24 V

~

25W max

Courtesy light: ..................................................................... 24 V

~

25W max

Gate-open warning light:........................................................24V

~

3W max

Power supply for accessories: ........................24V

~

(0.2 A max absorption)

Incorporated rolling-code radio receiver: ................. 433.92 MHz frequency
Coding: ................................................. rolling-code algorithm to be cloned
No. combinations: .......................................................................... 4 milliard
Antenna impedance: ...........................................................50 Ohm (RG58)
Max. no. radio transmitter to be memorised: ............................................ 63
Dimensions: ...............................................................................see figure 1
(* other voltages available on request)

4) TERMINAL BAR CONNECTIONS (Fig. 3)
WARNING – During wiring and installation, refer to the current standards 
as well as to principles of good technical practice.

Arrange  the  layout  of  the  electrical  installation,  making  reference  to  the 
current electrical CEI 64-8 and IEC 364 standards, HD384-harmonised, or 
other national standards. Keep the mains power supply connections distinctly 
separate from the service connections (photocells, electric edges, control 
devices etc.)

JP2

1-2 

Single-phase mains power supply (1=N) (2=L)

JP7

3-4 

Connection to motor 1:

 

3 - motor (BLUE wire)

 

4 - motor (BROWN wire)

5-18 

PHEBE-SQ lamp control output (fig. 3c) 

6-7 

24 V

electric lock or 24V 3W (DIP LG2) max. flashing light.

8-9 

24V

~

200mA max output – supply to photocells or other devices

10-11 

STOP button input (N.C.). If not used, leave the jumper bridged.

10-12 

START button input (N.O.)

13-14 

Motor opening limit switch (N.C.). If not used, leave the jumper 
bridged.

13-15 

Motor  closing  limit  switch  (N.C.).  If  not  used,  leave  the  jumper 
bridged.

16-17 

Connection to motor 2:

 

16 - motor (BLUE wire)

 

17 - motor (BROWN wire)

19-20 

24V

~

output for blinking light  (25W max) 

21-22 

Output (N.O. contact (24V

~

/0.5A max)) for gate-open warning light 

or alternatively 2nd radio channel (fig. 3a)

23-24 

24V

~

V safe 180mA max output – supply to photocell transmitters 

with check (fig. 3b)

25 

Photocell input (N.C,). If not used, leave jumper 10-25 bridged (fig. 
3b).

26 

Fault input (N.O.). Input for photocells provided with N.O. checking 
contact (fig. 3b). 

27-28 

Antenna  input  for  plug-in  radio-receiver  board  (27  signal  -  28 
braid)

JP3 (F)  JP4 (N)

230V

~

output to transformer

JP5 + JP6 -

24V

 input from transformer or battery back up

N.B. The board is provided with a series of pre-wired jumpers to make work 
easier for the installer.
The jumpers involve the following terminals: 10-11, 10-25, (13-14, 13-15 
PHEBE-SQ).  If  the  above-mentioned  terminals  are  used,  remove  their 
respective jumpers.

Содержание HYDRA-R

Страница 1: ...44 36015 Schio VI Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it HYDRA R 8 027908 235039 ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATION AND USER S MANUAL INSTRUCTIONS D UTILISATION ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO ...

Страница 2: ... HYDRA R Ver 05 D811425_05 ...

Страница 3: ...que momento le modifiche che essa ritiene convenienti per migliorare tecnicamente costruttivamente e commercialmente il prodotto senza impegnarsi ad aggiornare la presente pubblicazione USER S MANUAL ENGLISH Thank you for buying this product our company is sure that you will be more than satisfied with the product s performance The product is supplied with a Warnings leaflet and an Instruction boo...

Страница 4: ...iese für technische oder bauliche Verbesserungen als notwendig erachtet und die wesentlichen Produkteigenschaften unverändert bleiben FRANÇAIS MANUEL D UTILISATION FRANÇAIS Nous vous remercions pour avoir choisi ce produit Nous sommes sûrs qu il vous rendra le service nécessaire à vos besoins Lire attentivement le Manuel d instructions qui accompagne ce produit puis qu il fournit d importantes ind...

Страница 5: ...tar en cualquier momento las modificaciones que considere convenientes para mejorar técnica constructiva y comercialmente el producto sin la obligación de poner al día esta publicación MANUAL PARA DE USO PORTUGUÊS Agradecendolhe pela preferência dada a este produto a Empresa tem a certeza que do mesmo obterá as prestações necessárias ao seu uso Leia atentamente o opúsculo Manual de instruções que ...

Страница 6: ...ne dell apertura manuale in caso di emergenza Non permettere a persone e bambini di sostare nell area d azione del l automazione Non lasciare radiocomandi o altri dispositivi di comando alla portata dei bambini onde evitare azionamenti involontari dell automazione L utilizzatore deve evitare qualsiasi tentativo di intervento o riparazione dell automazione e rivolgersi solo a personale qualificato ...

Страница 7: ...se attiva consente di collegare una luce spia a 24V come in figura 3 In questo caso la luce indica la posizione del cancello come specificato nella tabella sopra Se non attiva l uscita ai morsetti 21 22 presenta un contatto libero da tensione e normalmente aperto che viene attivato solo per 2 secondi ad ogni pressione del tasto 2 del radiocomando associato Il tasto 1 è riservato per il comando di ...

Страница 8: ...NZIONE L operazione di autsettaggio va effettuata solo dopo aver verificato l esatto movimento dell anta apertura chiusura ed il corretto intervento dei finecorsa Non appena premuto il pulsante OK viene visualizzato il messaggio la centrale comanda una manovra di apertura seguita da una manovra di chiusura durante al quale viene automaticamente settato il valore minimo di coppia necessario al movi...

Страница 9: ...nte se si desidera tramite UNIPRO verificare il numero dei dispositivi collegati 121 1 Programmazione impianto centralizzato attraverso unipro Collegare il programmatore UNIPRO alla centralina tramite l accessorio UNIDA Vedere fig 5 Fare riferimento alle Istruzioni UNIPRO per ulteriori informazioni 12 2 Programmazione impianto centralizzato attraverso display Il programmatore a display presente ne...

Страница 10: ...e consente di uscire dal menu in cui si sta operando e tornare al precedente se avviene al livello principale del menu esce dalla programmazione e spegne il display Le modifiche apportate vengono confermate solo se seguite dalla pressione di OK Messaggio Attesa inserire valore o funzione OK RA ON OFF M P OK OK 11 ON OFF M P OK OK J ON OFF M P OK OK MRMA ON OFF M P OK OK R QR FMR ON OFF M P OK OK P...

Страница 11: ...MENU RADIO AGGIUNGI Consente di aggiungere un tasto di un radiocomando nella memoria della ricevente dopo la memorizzazione restituisce numero del trasmettitore nella locazione della memoria da 01 a 64 Aggiungi Tasto start associa il tasto desiderato al comando Start Aggiungi Tasto 2can associa il tasto desiderato al comando 2 canale radio LEGGI Effettua una verifica di un tasto di una ricevente s...

Страница 12: ...al automation activation Theusermustavoidanyattempttocarryoutworkorrepairontheautoma tion system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed Installation must be carried out using the safety devices and controls prescribed by the EN 12978 Standard 2 GENERAL OUTLINE The HYDRA R control panel is suit...

Страница 13: ...fied in the table above If not activated the output to terminals 21 and 22 shows a current free and normally open contact which is only activated for 2 seconds each time key 2 is pressed on the associated radio control device Key 1 is reserved for the Start command Photocells Test If this setting is not activated OFF it inhibits the photo cell checking function allowing connection of devices not p...

Страница 14: ...uring the photocells as well as using the START and STOP commands and the display At the end of this operation if autoset is successfully completed the con trol unit displays an OK message and after any key has been pressed it returns to the autoset menu Otherwise if the control unit displays a KO message it means that the autoset procedure has not been successfully completed it is therefore ne ce...

Страница 15: ...g a MASTER unit first of all which will have control over all the others to be necessarily set as SLAVE see logic menu Also set the Zone number see parameter menu between 0 and 127 The zone number allows you to create groups of automation units each one answering to the Zone Master unit Each zone can only be assigned one Master unit the Master unit in zone 0 also controls the Slave units in the ot...

Страница 16: ...ands No manoeuvres since latest maintenance in thousands No radio control devices memorised Press the OK key ACCESS TO MENUS Parameter increment reduction or ON OFF commutation Menu scrolling preceding following Press OK key Enter confirm Preset value OK message confirms modification made KO message value or function error Wait message enter value or function Simultaneously press the and keys Simu...

Страница 17: ... OK ERASE 64 Press P1 pushbutton on radio control device Press the required T key on radio control device see Fig B3 Release P1 on radio control device ADD 2ch hidden button release desired button 01 OK 01 t1 COD RX OK 1A9C OK 22FD OK 01 OK RADIO MENU ADD Allows you to add one key of a radio control device to the receiver memory after storage it displays a message showing the receiver number in th...

Страница 18: ... l utilisateur de l installation sur les systèmes de commande appliqués et sur l exécution de l ouverture manuelle en cas d urgence Ne pas permettre à des personnes et à des enfants de stationner dans la zone d action de la motorisation Nepaslaisserdesradiocommandesoud autresdispositifsdecommande à portée des enfants afin d éviter des actionnements involontaires de la motorisation L utilisateur do...

Страница 19: ...rture après l élimination de l obstacle Témoin de portail ouvert ou II canal radio s il est actif il permet de con necter un témoin à 24V comme indiqué à la figure 3 Dans ce cas la lumièreindiquelapositionduportailcommepréciséautableauci dessus S il n est pas actif la sortie aux bornes 21 22 présente un contact libre de tension et normalement ouvert qui est activé pendant 2 secondes seulement à ch...

Страница 20: ...1 OFF ON La suivante manœuvre à être commandée sera utilisée comme Autoset pour que cela se passe il est nécessaire que la manœuvre commence du fin de corse de fermeture À la fin de cette manœuvre la logique LG1 est automatiquement réglée sur OFF OFF Fonction déesactiver Logique 2 lg2 OFF ON Sortie bornes 6 7 comme feu clignotant branchement feu maxi 24V 3W OFF Sortie bornes 6 7 comme serrure élec...

Страница 21: ... et 127 Le numéro de zone permet de créer des groupes d automatismes dont chacun répond au Maître de Zone Chaque zone ne peut avoir qu un Maître le Maître de la zone 0 contrôle aussi les Esclaves des autres zones La fermeture en boucle de la connexion sérielle indiquée par la ligne hachurée à la Fig 5 n est nécessaire que si l on désire vérifier au moyen d UNIPRO le numéro des dispositifs connecté...

Страница 22: ...OK MM ON OFF M P OK Fig A Appuyer sur la touche OK ACCES AUX MENUS Incrément réduction paramètres ou commutation ON OFF Défilement du menu précédent suivant Appuyer sur la touche OK Retour validation Valeur prédéfinie 0 0 Message OK validation modification effectuée Message KO erreur valeur ou fonction Message Attente introduire la valeur ou la fonction Appuyer simultanément sur les touches et L a...

Страница 23: ...AJOUTER Permet d ajouter une touche d une commande radio dans la mémoire du récepteur après la mémorisation il affiche le numéro du récepteur dans l emplacement de la mémoire 01 à 64 Ajouter Touche start associe la touche désirée à la commande Start Ajouter Touche 2can associe la touche désirée à la commande 2 canal radio LIRE Effectue une vérification d une touche d un récepteur si mémorisé il af...

Страница 24: ...Anlage zu verweilen Keine Fernbedienungen oder andere Steuerungsvorrichtungen in Reich weite von Kindern liegenlassen Sie könnten die Anlage versehentlich in Gang setzen Der Betreiber hat jeden Versuch eines Eingriffes oder der Reparatur zu unterlassen Nur entsprechend qualifizierte Fachleute sind hierzu befugt Alles was nicht ausdrücklich in dieser Anleitung genannt ist ist untersagt Die Installa...

Страница 25: ...pe dieTorposition an wie aus der obigenTabelle hervorgeht Falls nicht aktiviert ist der Ausgang zu den Klemmen 21 22 ein spannungsfreier Arbeitskontakt der nur bei Betätigung von Taste 2 der zugeordneten Fernsteuerung für 2 Sekunden aktiviert wird DieTaste 1 ist für den Startbefehl reserviert TestLichtschranken Werdensiedeaktiviert OFF istdiePrüffunktionder Lichtschranken gesperrt Dann lassen sich...

Страница 26: ...nitt12 OFF Die Steuerung wird als Slave in einer zentralgesteuerten Anlage konfiguriert siehe Abschnitt12 Logik 1 lg1 OFF ON Der nächste durch einen Befehl veranlaßte Vorgang wird als Autoset gefahren dazu ist es notwendig daß der Vorgang vom Punkt des Schließ Endschalters beginnt Am Schluß dieses Vorganges wird die Logik LG1 automatisch auf OFF gesetzt OFF Funktion deaktiviert Logik 2 lg2 OFF ON ...

Страница 27: ...affierung in Fig 5 dargestellt ist nur erforderlich wenn mittels UNIPRO die Anzahl der angeschlossenen Vorrichtungen geprüft werden soll 12 1 Programmierung zentralgesteuerte Anlage mit Unipro Verbinden Sie den Programmierterminal UNIPRO über das Zubehörteil UNIDA mit der Steuerung siehe Fig 5 Weitere Informationen können der Betriebsanleitung UNIPRO entnommen werden 12 2 Programmierung zentralges...

Страница 28: ...ungen OK LEGENDA P OK ON OFF Erhöhung Verringerung Parameter oder Umschaltung ON OFF Menüdurchlauf vorheriges nächstes Taste OK drücken Enter Bestätigung Voreinstellungswert Meldung OK Bestätigung der Änderung Meldung KO Fehler Wert oder Funktion Meldung Warten Wert oder Funktion eingeben Gleichzeitig die Tasten und drücken Die gleichzeitige Betätigung der Tasten und gestattet das Verlassen des Me...

Страница 29: ...rspeicher die Taste einer Fernsteuerung hinzu nach der Speicherung erfolgt a u f d e m D i s p l a y e i n e R ü c k m e l d u n g m i t d e r Empfängernummer am Speicherplatz 01 bis 64 HINZUFÜGENTaste start Weist die gewünschte Taste dem Startbefehl zu HINZUFÜGENTaste 2ch Weist die gewünschte Taste dem Befehl 2 Funkkanal zu LESEN Prüft eine Empfängertaste die falls g e s p e i c h e r t a u f d e...

Страница 30: ...emas de mando aplicados y la ejecución de la apertura manual en caso de emergencia No permitir que personas o niños estacionen en el campo de acción del automatismo No dejar radiomandos u otros dispositivos de mando al alcance de los niños para evitar el accionamiento involuntario del automatismo El usuario debe evitar cualquier intento de intervención o reparación del automatismo y dirigirse únic...

Страница 31: ...de la cancela y su reapertura una vez que el obstáculo haya sido apartado Luz de aviso de cancela abierta o II canal radio si resulta activado permite conectar una luz de aviso de 24 V como se ilustra en la fig 3 En este caso la luz indica la posición de la cancela como se especifica en la tabla superior Si no resulta activado la salida de los bornes 21 22 presenta un contacto libre de tensión y n...

Страница 32: ...xión centralizada Lógica 1 lg1 OFF ON La sucesiva maniobra que se ordenará será utilizada como Autoset para que esto se produzca es necesario que la maniobra empiece a partir del fin de carrera de cierre Al término de esta maniobra la lógica LG1 se configurará automáticamente en OFF OFF Función desabilitada Lógica 2 lg2 OFF ON Salida bornes 6 7 como luz intermitente conexión luz de 24V 3W máx OFF ...

Страница 33: ... zona 0 controla también los Slave de las otras zonas El cierre a modo de anillo de la conexión serial indicado con una línea punteada en la Fig 5 es necesario únicamente si se desea mediante UNIPRO verificar el n de dispositivos conectados 12 1 Programación de la instalación centralizada a través de Unipro Antetodo esprecisoconectarelprogramadorUNIPROalacentralmediante el accesorio UNIDA véase la...

Страница 34: ...tenimiento expresado en millares No de radiomandos memorizados OK LEGENDA P OK ON OFF Incremento reducción parámetros o conmutación ON OFF Corrimiento menús anterior sucesivo Presione la tecla OK Intro confirmación Valor predefinido Mensaje OK confirmación realización modificación Mensaje KO error valor o función Mensaje Espera introducir valor o función Presione simultáneamente las teclas y La pr...

Страница 35: ...g r e g a r u n a t e c l a d e u n radiomando en la memoria del receptor Después de la memorización el display visualiza en qué posición de la memoria ha sido memorizado el radiomando número de 01 a 64 ANADIRTecla start asocia la tecla deseada al comando Start ANADIR Tecla 2ch asocia la tecla deseada al comando 2 canal radio LEER Efectúa un control de una tecla de un receptor En caso de memorizac...

Страница 36: ...de emergência Não permita a pessoas e crianças de ficarem paradas na área de acção da automatização Nãodeixeradiocomandosououtrosdispositivosdecomandoaoalcancede crianças para evitar accionamentos involuntários da automatização O utilizador deve evitar qualquer tentativa de intervenção ou reparação da automatização e valer se unicamente de pessoal qualificado Tudo aquilo que não é expressamente pr...

Страница 37: ...ue o obstáculo tiver sido removido Indicador luminoso de portão aberto ou II canal rádio se estiver activa consente de ligar um indicador luminoso de 24V como na figura 3 Neste caso a luz indica a posição do portão tal como especificado na tabela acima Se não estiver activa a saída para os bornes 21 22 apresenta um contacto sem tensão e normalmente aberto que é activado só por 2 segundos cada vez ...

Страница 38: ...mpada 24V 3W máx OFF Saída terminais 6 7 como fechadura eléctrica 7 MENU CONFIGURAÇÃO AUTOMÁTICA AUTOSET Consente de efectuar a configuração automática do Binário dos motores ATENÇÃO A operação de configuração automática deve ser efectuada só depois de ter se verificado o exacto movimento da folha abertura fecha mento e a correcta activação dos finais de curso Assim que se pressiona o botão OK é v...

Страница 39: ...ogramação da instalação centralizada com unipro Ligar o programador UNIPRO à central utilizando o acessório UNIDA Ver Fig 5 Consultar as instruções de UNIPRO para ulteriores informações 12 2 Programação da instalação centralizada com display O programador com display presente na placa consente de definir todas as funçõesdoquadrodecomandosHYDRA R TomarcomoreferênciaaFig Ae B No menu PARAM define se...

Страница 40: ... menu em que se está a operar e voltar para o precedente se isto acontece no nível principal do menu sai se da programação e desliga se o visor As modificações efectuadas são confirmadas só se em seguida pressiona se OK P M A OK OK P OK OK RA OK OK P N NCPR OK OK P N AGCPP OK RA ON OFF M P OK OK N QMQ ON OFF M P OK OK J N ON OFF M P OK OK MRMA ON OFF M P OK OK R QR FMR ON OFF M P OK OK P ON OFF M ...

Страница 41: ... 01 PRG LEER MENU RÁDIO ADICIONAR Consente de adicionar uma tecla de um radiocomando na memória do receptor depois do armazenamento o visor mostra o número do receptor na localização da memória de 01 a 64 ADICIONARTecla start associa a tecla desejada ao comando Start ADICIONARTecla 2can associa a tecla desejada ao comando 2 canal rádio LER Efectua uma verificação de uma tecla de um receptor se arm...

Страница 42: ...2 IIoCH R SCA PHEBE Lock PHOT FAULT JP9 8 9 21 SCA IIo CH 22 JP9 19 20 21 22 24 V A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SERVICE SWO COM SWC M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PHEBE SQ HYDRA R HYDRA R PHEBE SQ SWO COM SWC PHEBE SQ 16 17 5 18 HYDRA R 13 14 15 LUX PHEBE C 1 2 1 2 3 4 5 24 23 9 8 TX1 RX1 10 26 25 1 2 1 2 3 4 5 24 23 9 8 TX1 RX1 26 10 1 2 1 2 3 4 5 24 23 9 8 TX2 RX2 10 25 B BL...

Страница 43: ...tos Contatos UNITRC UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos UNIMITTO UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos Fig 4 Fig 4 1 3 4 1 2 2 3 4 1 3 4 1 2 2 3 4 UNIMITTO UNITRC P1 Contatti Contacts Contacts Kontakte Contactos Contatos P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 ...

Страница 44: ...Fig 5 HYDRA R SCS1 HYDRA R SCS2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 HYDRA R SCS2 Max 250m SCS HYDRA R JP9 ...

Отзывы: