ENGLISH
INSTALLATION MANUAL
Terminal
Deinition
Description
P
o
w
er supply
L
LINE
Single-phase power supply
220-230V ~50/60 Hz*
N
NEUTRAL
JP31
TRANSF PRIM
Transformer primary winding connection, 220-230V
~
.
JP32
JP13
TRANSF SEC
Board power supply:
24V~ Transformer secondary winding
M
ot
or
10
MOT +
Connection motor 1
11
MOT -
Au
x
20
AUX 0 -BLINKER
24V (N.O.) (MAX. 1A)
Contact stays closed while leaf is operating.
21
Limit
swit
ches
41
+REF SWE
Limit switch common
42
SWC
Closing limit switch SWC (N.C.)
43
SWO
Opening limit switch SWO (N.C.)
A
cc
essories
p
o
w
er
supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
C
ommands
60
Common
START and OPEN inputs common
61
Only active on FW < 3.03
START
START command button (N.O.).
Operation according to “3/4-STEP” logic
Only active on FW ≥ 3.03
START
START command button (N.O.).
Operation according to “Residential / apartment building operation” logic
62
OPEN
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the contact is opened.
When the contact is open, the automated device closes following the TCA time, where activated.
S
af
et
y de
vic
es
70
Common
STOP, PHOT and BAR inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
PHOT (*)
PHOTOCELL input (N.C.).
Operation according to “PHOTOCELL/PHOTOCELL DURING CLOSING” logic. If not used, leave jumper inserted.
73
FAULT 1
Test input for safety devices connected to PHOT.
74
Only active on FW < 3.03
BAR (*)
BAR safety edge input (N.C.).
Conigurable according to the “BAR/ 8K2” logic.
The command reverses movement for 2 sec.
If not used, leave jumper inserted.
Only active on FW ≥ 3.03
BAR /
BAR CL /
BAR TEST /
BAR CL TEST /
BAR 8K2 /
BAR CL 8K2
(*)
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
Safety
edge
check dip
Safety edge
operation
dip
OFF
OFF
OFF
NC input, no veriication, reversal while opening and closing
(BAR)
OFF
OFF
ON
NC input, no veriication, reversal only when closing, stop when
opening
(BAR CL)
OFF
ON
OFF
NC input, with veriication, reversal while opening and closing
(BAR TEST)
OFF
ON
ON
NC input, with veriication, reversal only when closing, stop when
opening
(BAR CL TEST)
ON
OFF
OFF
8K2 input, reversal when opening and closing
(BAR 8K2)
ON
OFF
ON
8K2 input, reversal only when closing, stop when opening
(BAR
CL 8K2)
ON
ON
OFF
---
ON
ON
ON
---
75
FAULT 2
Test input for safety devices connected to BAR.
A
n
tenna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies
close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna
to a more suitable position.
#
SHIELD
*) If “D” type devices are installed (as deined by EN12453), connect in unveriied mode, foresee mandatory maintenance at least every six months.
TABLE “A” - PARAMETERS
TRIMMER
Parameter
+
min.
+
max.
Description
T1
Automatic
closing time [s]
0
120
Waiting time before automatic closing.
NOTE: Set to 0 if not used.
T2
Leaf force [%]
10
90
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
WARNING: It afects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
T3
Slow-down
distance [%]
5
50
Set opening slow-down speed as a percentage of total travel. This distance is travelled at low speed.
NOTE: When this parameter is edited, a new Autoset cycle must be run to conirm it.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
DEIMOS BT A 400 - DEIMOS BT A 600
-
25
D811972 00100_10