28
MOD.
BEZZERA BZ16
DIRECT WATER CONNECTION mode.
The transformation from TANK to DIRECT WATER
CONNECTION mode implies a pressure varia-
tion, detected by the pump pressure gauge (Fig.
01; pos. 15), which can be reset by operating the
adjustment joint (Fig. 12; pos. 1) as described in
paragraph 4.3.3 of this booklet.
4.3.1 BZ16 “TOP-DIRECT WATER
CONNECTION” MODE
The machine is delivered in TANK mode; to trans-
form it in DIRECT WATER CONNECTION mode,
proceed as follows:
- Make sure that the machine is not connected
to the power mains and that all its parts are
cold.
- Remove the tank (Fig. 10; pos. 1), position
the plug with its seals (Fig. 10; pos. 3) fully
screwing it and connect the tank probe bypass
to the specific tongue located on the tank sup-
port (Fig.10; pos. 2).
- Remove the plug with its seal (Fig. 11; pos. 2)
and replace it with the water load tube (Fig.
11; pos. 1) provided, taking care not to dam-
age and/or scratch the any part of the ma-
chine.
For connection to the water mains, comply with
paragraph 4.2.2. of this booklet.
4.3.2 BZ16 “TOP-TANK” MODE
It is possible to restore the TANK mode, returning
the machine to the original delivery mode, acting
as follows:
- Make sure that the water tap is closed and that
the machine is not connected to the power
mains and that all its parts are cold.
- Remove the water load tube (Fig. 11; pos. 1)
and replace it with the plug and its seal (Fig.
11; pos. 2) taking care not to damage and/or
scratch any part of the machine.
- Remove the cap with its seals (Fig. 10; pos. 3),
disconnect the tank probe bypass cable from
the specific tongue located on the tank sup-
port (Fig.10; pos. 2) and reposition the tank
(Fig. 10; pos. 1) in its original position.
4.3.3 BZ16 VERSION “TOP” - PUMP
ADJUSTMENT
After the transformation, it is possible to change
the operating pressure, returning it to 9 bars (0,9
MPa) as set in factory, screwing or unscrewing the
adjustment joint located in the bottom section of
the machine (Fig. 12; pos. 1).
After performing the operations described in par-
agraphs 5.1 and 5.2 of this booklet, operate as
follows:
1 - Insert the filter holder with blind filter (Fig. 09;
pos. 16) in its seat.
2 -
Start up coffee distribution (Fig. 04; pos. 2a-
2d), take note of the pressure and Stop coffee
distribution
.
3 - Unscrew the counternut (Fig. 12; pos. 2).
4 - Screw the pump adjustment joint (Fig. 12; pos.
1) to increase pressure or unscrew to decrease,
performing no more than a complete turn at a
time.
Repeat operations 2 and 4 until the pressure of
the pump during dispensing is returned to 9 bars
(0.9 MPA) or however between 8 and 10 bars
(0.8 and 1.0 MPa).
5 - Screw the counternut (Fig. 12; pos. 2).
Attention
:
- Do not remove the filter holder with blind filter
when the machine is operating.
- Do not set the pump pressure above 10.5 bars
(1.05 MPa).
5 - USE OF THE MACHINE
5.1 First machine start and water
loading in the boiler
Open the water interception tap (R version).
Pour water into the tank, (S Version) (Fig. 03).
Warnings:
- Use drinking water with water hardness in
French degrees of about 6°F; never use hot
Содержание BZ16
Страница 2: ......
Страница 5: ...5 MOD BEZZERA BZ16 3 0 16 0 FIG 03 FIG 05 2a 2b 2c 2d 2e...
Страница 6: ...6 MOD BEZZERA BZ16 FIG 07 FIG 08 1 FIG 09 FIG 06 16 17 18...
Страница 7: ...7 MOD BEZZERA BZ16 2 1 2 3 1 FIG 11 FIG 10 A 2 1 1 2 FIG 12...
Страница 68: ...NOTE...
Страница 69: ...NOTE...
Страница 70: ...NOTE...
Страница 71: ......