background image

12

Contents

Included in delivery

For details of the delivery scope, see description of the 

device and accessories on page 14.

• Nebuliser and accessories

• Mesh atomiser with medicine container

• Mouthpiece

• Connecting piece

• Adult mask

• Child mask

• Power pack

• 4 x AA 1.5 V batteries

• These instructions for use

• Storage bag

1. Getting to know your instrument

Dear customer

thank you for choosing one of our products. Our brand 

stands for well-engineered, quality made products; 

driven by innovation and safety. Our product range 

encompasses a wealth of products for health and well-

being in the heat, weight, blood pressure, body tem-

perature, pulse, gentle therapy, massage, beauty, baby 

and air sectors.

Please read these instructions for use carefully and 

keep them for later use, be sure to make them ac-

cessible to other users and observe the information 

they contain.
With kind regards

Your Beurer team

Area of application

This nebuliser is a mesh atomiser for treating the up-

per and lower respiratory tract.

The nebulisation and inhalation of medication pre-

scribed or recommended by a doctor can prevent 

against diseases of the respiratory tract, treat the side 

effects of these disorders and accelerate healing.

For more information on possible applications, consult 

your doctor or pharmacist.

The device is suitable for inhalation at home. Medicines 

should only be inhaled when instructed by a doctor. 

Inhalation should be performed in a calm and relaxed 

atmosphere. Inhale slowly and deeply to enable the 

medicine to reach the small bronchi deep into the 

lungs. Exhale normally.
Once prepared, the device is suitable for reuse. Recon-

ditioning includes the replacement of all accessories in-

cluding the mesh atomiser, as well as the disinfection of 

the surface of the device using a standard disinfectant.

Please note that all accessories should be replaced if 

the device is used by more than one person.

We therefore recommend that you replace the atom-

iser and other accessories after a year.

2. Signs and symbols

The following symbols appear in these instructions.

 Warning

    Warning instruction indicating a 

risk of injury or damage to health.

 Important

    Safety note indicating possible 

damage to the unit/accessory.

 Note

  

Note on important information.

The following symbols are used on the packaging and 

on the nameplate of the device and accessories.

Type BF applied part

Follow instructions for use

Manufacturer 

On / Off

SN

Serial number 

Device in protection class 2

Do not use outdoors

IP 22

Protected against foreign objects equal 

to or greater than 12.5 mm in diameter 

and against drops of water falling at up 

to 15° from vertical
The CE labelling certifies that the 

product complies with the essential 

requirements of Directive 93/42/EC on 

medical products.

ENGLISH

  1. Getting to know your instrument .......................12

  2. Signs and symbols ............................................12

  3. Safety information and warnings .......................13

  4. Useful information on the device .......................14

  5.  Description of device and accessories..............14

  6. Initial use............................................................15

  7. Operation ...........................................................16

  8. Cleaning and disinfection ..................................16

  9. Technical specifications ....................................19

10.  Replacement parts and wearing parts ..............19

11. Disposal .............................................................20

Содержание IH50

Страница 1: ...er Instructions for use 12 F Inhalateur Mode d emploi 21 E Inhalador Manual de instrucciones 31 I Inalatore Istruzioni per l uso 41 T Inhalat r Kullan m k lavuzu 50 r 59 Q Inhalator Instrukcja obs ugi...

Страница 2: ...d atmosphere Inhale slowly and deeply to enable the medicine to reach the small bronchi deep into the lungs Exhale normally Once prepared the device is suitable for reuse Recon ditioning includes the...

Страница 3: ...our local dealer The IH 50 must only be operated using the appropri ate Beurer accessories The use of other accessories can impair therapeutic efficiency and may damage the device Remove the batteries...

Страница 4: ...e protective gloves Repairs Note Never open or attempt to repair the unit yourself as otherwise proper function is no longer guaranteed Fail ure to observe this regulation shall void the warranty If y...

Страница 5: ...ration on the bottom of the casing Fold the battery com partment lid down again and push it back in place in the opposite direction to the arrows Note When changing batteries ensure that the medicine...

Страница 6: ...they can enter the air ways and lungs you must inhale slowly and deeply hold your breath briefly 5 to 10 seconds and then exhale quickly You should only use nebulisers to treat respiratory disorders...

Страница 7: ...be poisonous when in contact with the skin or mucous membranes or when swallowed or inhaled If required you can clean the device casing with a lightly moistened cloth that has been soaked in mild soap...

Страница 8: ...mpletely by shaking it Otherwise nebulisation may not function properly after reassembling the device If this is the case disassemble the mesh atomiser 3 again and shake it so that the water can escap...

Страница 9: ...frequency 100 kHz Housing material ABS TPE Mains connection 100 240 V 50 60 Hz 0 15 A Operating conditions Temperature 5 C 40 C Relative humidity 80 non con densing Storage and transport conditions Te...

Страница 10: ...ion of this device 11 Disposal Battery disposal The empty completely flat batteries must be dis posed of through specially designated collection boxes recycling points or electronics retailers You are...

Страница 11: ...it s effectuer que sur avis m dical Soyez calme et d tendu pour proc der l inhalation Inspirez lentement et profond ment afin que le m dicament parvienne jusqu aux bronches les plus fines et les plus...

Страница 12: ...ant N immergez pas l appareil sous l eau et ne l utilisez pas dans des locaux humides Aucun liquide ne doit p n trer dans l appareil Prot gez l appareil contre les chocs importants Si l appareil est t...

Страница 13: ...g es ni court cir cuit es En cas de non utilisation prolong e de l appareil sortez les piles du compartiment piles Utilisez uniquement des piles identiques ou quiva lentes Remplacez toujours l ensembl...

Страница 14: ...2 positionnez le n buliseur en mailles 3 bloquez le en le tournant dans le sens des aiguilles d une montre jusqu ce que les lectrodes de contact argent es pointent vers le bas Montez le r ci pient av...

Страница 15: ...le couvercle 1 de l appareil 2 Remplissage du n buliseur Ouvrez le r cipient m dica ments 2 en ouvrant l trier et remplissez le r cipient m dicaments avec une solution de chlorure de sodium isoto niqu...

Страница 16: ...n d viter tout risque pour votre sant Le n buliseur et les accessoires sont destin s un usage multiple Diff rentes exigences en mati re de nettoyage et de pr paration hygi nique existent pour les diff...

Страница 17: ...halation sans interruption car un long intervalle entre les inhalations pourrait obstruer le n buliseur en mailles et donc affec ter l efficacit du traitement D sinfection Veuillez suivre scrupuleusem...

Страница 18: ...transportez pas avec des objets humides Rangez et transportez l appareil et les accessoires l abri des rayons directs du soleil D pannage Probl mes questions Cause possible solution Le n buliseur ne...

Страница 19: ...r serve de modifications techniques Les pi ces d usure sont exclues de la garantie Le num ro de s rie se trouve sur l appareil ou sur le compartiment piles Les mesures ont t effectu es avec une solut...

Страница 20: ...mpl tement d charg es doivent tre mises au rebut dans des conteneurs sp ciaux ou aux points de collecte r serv s cet usage ou bien d pos es chez un revendeur d appa reils lectriques L limination des p...