Blade Changing
– Large Tools (Continued)
Blade Installation - Large Tools (continued)
Models: 750, 850, 1000, 1300, 1400, 1500, 1850, 1880
Blade is too tight
If the blade is too tight in the
housing, adjustments can be
made by loosening the left cover
retaining screw and slightly
spreading open the housing.
Check the housing for proper
running clearance and retighten
the left cover screw to 35 in-lb.
(4 N-m). Use of the Bettcher
torque wrench kit is
recommended.
Refer to Section
7, Tools
Blade is too loose
If the blade is too loose in the housing, adjustments can be made by slightly loosening the
left cover retaining screw and squeezing the housing lightly. Check the housing for
proper running clearance and retighten the left cover screw to 35 in-lb. (4 N-m). Use of
the Bettcher
®
torque wrench kit is recommended.
Refer to Section 7, Tools.