WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS.
WARNING –
To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
A wire connector is provided on this unit to connect a minimum 6 AWG (13.3 mm
2
)
solid copper conductor between this unit and any metal equipment, metal
enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of
the unit.
DANGER –
Risk of injury.
a) Replace damaged cord immediately.
b) Do not bury cord.
c) Connect to a grounded, grounding type receptacle only.
WARNING –
This product is provided with a ground-fault circuit-interrupter integrated
with the power plug at the end of the cord. The GFCI must be tested before each
use. With the product operating, push the test button on the GFCI and the product
should not operate. Push the reset button on the GFCI and the product should now
operate normally. When the product fails to operate in this manner, there is a ground
current flowing indicating the possibility of an electrical shock. Disconnect the power
until the fault has been identified and corrected.
DANGER –
Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use this spa unless they are supervised at all times.
DANGER –
Risk of Injury. The suction fittings in this spa are sized to match the
specific water flow created by the pump. Should the need arise to replace the suction
fittings or the pump, be sure that the flow rates are compatible. Never operate spa if
the suction fittings are broken or missing. Never replace a suction fitting with one
rated less than the flow rate marked on the original suction fitting.
DANGER –
Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each
metal surface is permanently connected by a minimum 6 AWG (13.3 mm
2
) solid copper
conductor to the wire connector on the terminal box that is provided for this purpose.
DANGER –
Risk of Electric Shock. Do not permit any electric appliance, such as a
light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
WARNING –
To reduce the risk of injury:
a) The water in a spa should never exceed 40°C (104°F). Water temperatures
between 38°C (100°F) and 40°C (104°F) are considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when spa
3
use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly pregnant
women should limit spa water temperatures to 38°C (100°F).
c) Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of water temperature-regulating devices
varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa.
f ) Persons using medication should consult a physician before using a spa since
some medication may induce drowsiness while other medication may affect heart
rate, blood pressure, and circulation.
WARNING:
TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS
RAINING.
WARNING:
Water attracts children; Always attach a spa cover after each use.
WARNING:
TO REDUCE THE RISK OF INJURY: Never add water that is higher than
40°C (104°F) into the Spa.
CONSULT YOUR PHYSICIAN FOR RECOMMENDATIONS.
CAUTION:
The spa should not be setup or left out in temperatures lower than
4°C (40°F).
CAUTION:
Do not use the spa alone.
CAUTION:
Always enter and exit the spa slowly and cautiously. Wet surfaces are
slippery.
CAUTION:
To avoid damage to the pump, the spa must never be operated unless
the spa is filled with water.
CAUTION:
Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE:
Please examine equipment before use. Notify Bestway
®
at the customer
service address listed on this manual for any damaged or missing parts at the time of
purchase. Verify that the equipment components represent the model that you had
intended to purchase.
SAVE THESE INSTRUCTIONS
WARNING:
CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT ADULT
SUPERVISION.
WARNING:
DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS ARE
INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARNING:
PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL
HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING:
PEOPLE WITH INFECTIOUS DISEASES SHOULD NOT USE A SPA OR HOT
TUB.
WARNING:
TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING THE SPA
OR HOT TUB.
WARNING:
DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE OF A SPA
OR HOT TUB TO AVOID UNCONSCIOUSNESS AND POSSIBLE DROWNING.
WARNING:
PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A
PHYSICIAN BEFORE USING A SPA OR HOT TUB.
WARNING:
WATER TEMPERATURE IN EXCESS OF 38°C (100°F) CAN BE INJURIOUS TO
YOUR HEALTH.
WARNING:
BEFORE ENTERING THE SPA OR HOT TUB, MEASURE THE WATER
TEMPERATURE WITH AN ACCURATE THERMOMETER.
WARNING:
DO NOT USE A SPA OR HOT TUB IMMEDIATELY FOLLOWING STRENUOUS
EXERCISE.
S-S-005136