6 Usage
Shields for Flange Mounting
34
44192BA2, Rev.03, 07/2021
When using a flexible shaft (Fig. 16, item 2): Open the respective clamping
screw (Fig. 16, item 5; item 6) and move the source into the desired
measurement position. Via the clamping screw, set the desired depth of
immersion into the dip pipe.
When using a source magazine (Fig. 16, item 10): Remove the handle bar
(Fig. 16, item 9) from the shutter and screw it in the centre of the magazine.
Turn the magazine to the next position segment which allows you to release
the magazine into the dip pipe adapter.
IMPORTANT
Proceed to the next section when using a source magazine shield for dip pipe
adapter (grayloc tubes).
j
WARNING
Danger of injury by falling loads!
Assemble and disassemble the shield head with a crane and exclusively use
the lifting eyes for attaching the sling gear.
2.
Attach and screw the shield head / cover (Fig. 16, item 7).
3.
Secure the shield head / cover with the padlock (Fig. 16, item 8).
Commissioning is complete.
Shield with Source Magazine for Dip Pipe Adapters
IMPORTANT
The magazine is located inside the dip pipe adapter!
5.
Remove the handle bar (Fig. 16, item 9) and attach it to the shutter again.
6.
Slide the shutter in position
CLOSED
and lock it.
7.
Close the cover (shield head: Fig. 13, item 2) of the shield, screw and lock it.
Store the handle bar at it intended storing position.
NOTICE
To close the dip pipe adapter, observe the instructions of the plant operator.
8.
Remove the shield and store in a proper way. Note all information in chapter
5 Installation.
9.
Close the cover of the dip pipe adapter.
Commissioning is complete.