Shields for Flange Mounting
6 Usage
44192BA2, Rev.03, 07/2021
33
4.
Secure the Shutter in the new position with the padlock (only with slide
shutters).
The sources can now be brought individually into the measuring
position, see chapter 6.2.2.
6.2.2
Inserting the Source into the Dip Pipe
The sources are marked with numbers. Pay attention to the numbering to ensure
the order in which you insert the individual sources into the dip pipe.
1
2
3
4
5
Coupling element with steel rope
Coupling element with flexible shaft
Positioning stopper
Fixing screw (hex socket screw)
Clamping screw (hex socket screw)
6
7
8
9
10
Clamping screw (knurled head
screw)
Shield head / cover
Padlock
Handle bar
Source magazine
Fig. 16
Inserting the sources / source magazine
1.
Use the steel rope or the flexible shaft to move all sources into the desired
measurement position subsequently.
NOTICE
Insert the source with the lowest measuring position into the dip pipe first.
When using a steel rope (Fig. 16, item 1): Via the positioning stopper (Fig.
16, item 3) at the steel rope, set the desired depth of immersion into the dip
pipe. Tighten the fixing screw (Fig. 16, item 4) on the stopper to 2 Nm. Open
the respective clamping screw (Fig. 16, item 5; item 6) and lower the source
on the steel rope until it reaches the set depth of immersion into the dip
pipe.