7.1.1

 

Temperature Coefficients 

 
 

 
 

 
 

 

Note: 

Water temperature coefficients can be used 
for many low concentration products, such 

as milk, beer, whey, starch suspension, etc. 
For upgraded milk, whey, cottage cheese, 

etc. the values given for sugar solution can 
be used with good approximation. 

 g/cm3

 g/l 

 %

 

 °Be

 H2O - H2SO4

20

 

30

 

5,9500E-04

1,0220E+00

8,0000E-02

5,3100E-03

 

 

50

 

30

 

6,9500E-04

1,9320E+00

1,0300E-01

7,7300E-03

 

 

80

 

30

 

1,0150E-03

2,5190E+00

1,0000E-01

4,9900E-03

 

 

20

 

60

 

6,3500E-04

1,1070E+00

8,8000E-02

1,2920E-02

 

 H2O - NaOH

 

10

 

30

 

0,00047

0,528

 

0,04315

0,00436

 

30

 

30

 

0,00062

0,974

 

0,05964

0,00308

 

50

 

30

 

0,00072

1,44

 

0,0759

0,00684

 

10

 

60

 

0,00055

0,628

 

0,0521

0,0064

 

30

 

60

 

0,00065

1,02

 

0,0634

0,00353

 

50

 

60

 

0,0007

1,404

 

0,075

0,00681

 H2O - HCl

10

 

25

 

3,3000E-04

7,3600E-01

 

6,7200E-02

2,9300E-03

 

 

30

 

25

 

6,0000E-04

1,5720E+00

1,2150E-01

8,0000E-03

 

 

10

 

75

 

5,3800E-04

1,1960E+00

1,1160E-01

4,1450E-02

 

 

30

 

75

 

5,7600E-04

1,6610E+00

1,3330E-01

4,4380E-02

 

 Sugar sol.

10

 

20

 

0,0002377

 

0,621

 

0,05748

0,000823

 

 

30

 

20

 

0,000341

0,908

 

0,07144

0,001245

 

 

50

 

20

 

0,000436

1,196

 

0,0794

0,001488

 

 

70

 

20

 

0,000518

1,457

 

0,0855

0,00355

 

10

 

50

 

0,000472

1,247

 

0,1167

0,00339

 

30

 

50

 

0,000582

1,395

 

0,1111

0,00302

 

50

 

50

 

0,000559

1,536

 

0,1033

0,00254

 

70

 

50

 

0,000588

1,654

 

0,0983

0,00475

10

 

70

 

0,000582

1,538

 

0,145

0,00531

30

 

70

 

0,000608

1,631

 

0,131

0,00426

50

 

70

 

0,000627

1,718

 

0,117

0,00328

70

 

70

 

0,000632

1,768

 

0,106

0,00561

10

 

80

 

0,000632

1,665

 

0,1583

0,00636

30

 

80

 

0,000649

1,173

 

0,1401

0,00491

50

 

80

 

0,000658

1,794

 

0,1223

0,00365

70

 

80

 

0,000641

1,785

 

0,1072

0,00582

 Input value at 

Aver. 

temp.

 

in °C

 Product

 

 Concen-
 tration in

 

 Gew. %

Input value
at g/cm3

 

 

10

 

1,5000E-04

 

 

20

 

2,0300E-04

 

 

30

 

2,9900E-04

 

 

40

 

3,8000E-04

 

 

50

 

4,5700E-04

 

 

60

 

5,1300E-04

 

 

70

 

5,7100E-04

 

 

80

 

6,2350E-04

 

 

90

 

6,7000E-04

 Water 

 Temp.

in °C

 

Содержание LB 3602

Страница 1: ...Measuring Path LB 379 and LB 3602 3603 Operating Manual 40437BA2 Rev No 00 12 2016...

Страница 2: ...LB 379 2...

Страница 3: ...6 2 1 4 Installation of the Resistance Thermometer Pt 100 16 3 WATER COOLING IN THE MEASURING PATH LB 379 17 3 1 Cooling Water Requirement 17 4 ELECTRICAL CONNECTIONS 18 4 1 Detector 18 5 TECHNICAL DA...

Страница 4: ...LB 379 4...

Страница 5: ...his measuring device Radiation Protection Instructions This measuring system uses radioactive sources The radiation protection information in this operating manual and the relevant statutory provision...

Страница 6: ...e of light the function involved is a square function i e doubling the distance reduces the radiation intensity to if all other condi tions remain unchanged In the measuring paths LB 379 and LB LB3602...

Страница 7: ...ined contaminations by hydrocarbons may occur for example by sugar or cellulose in varying proportions The lower absorption coefficient of the impurity results in a lower influence on the measurement...

Страница 8: ...sured The measuring device generally comprises the following components a the measurement path with radioactive source through pipe for the product to be measured detector b the evaluation unit c the...

Страница 9: ...us measurement Discontinuous measurement Batch operation via keyboard press run button Batch operation via digital input 1 3 1 Setting the Detector Code Internal device parameters are adjusted to suit...

Страница 10: ...ted exit of the useful radiation only in the direction of the product pipe The radiation is shielded by the lead shielding 2 and by the case even if the pipeline is empty so that no additional protect...

Страница 11: ...ring path LB 3602 LB 4491 05 0x Gd E Ex protection EEx de II CT6 Figure 4 Measuring path LB 3602 3603 The measuring path LB 3602 can be used in potentially explosive areas or with the measuring path L...

Страница 12: ...pulses The count rate transmitted to the evaluation unit is proportional to the radiation intensity received The detector is equipped with an automatic drift compensation which automatically corrects...

Страница 13: ...tampered with or damaged Very important Please read the Radiation Protection Guidelines in chapter Radi ation Protection and observe them strictly 2 1Installation of the Measuring Path 2 1 1 Safety I...

Страница 14: ...e please keep in mind a The pipeline must always be completely filled at the measuring site with the product to be measured during the operation b Corrosion abrasion or wall deposits must not occur at...

Страница 15: ...ever the measurement covers the entire diameter of the product in the path or radiation Therefore the measurement result is not representative no gas bubbles are present in the path of radiation suspe...

Страница 16: ...ay be disassembled only at max 40 C so that the sealing surfaces are not damaged If a flange connection leaks although all screws are tightened NO LONGER TIGHTEN but loosen the screws on the side oppo...

Страница 17: ...efficiency The minimum cooling water requirement Qmin can be calculated for the measuring path LB 379 using the following formula W U T T T 313 10 75 9 323 5 5 323 Q 11 4 4 Pr min Qmin cooling water r...

Страница 18: ...tion unit and detector They are listed in chapter 5 When installing the connection cable make sure that water cannot get into the connection box via the cable At ambient temperatures 70 C the installe...

Страница 19: ...sion special form Measuring pipe ND 65 NP 10 material stainless steel 1 4571 or 1 4401 in lined pipes 1 4301 Connections Flanges according to DIN 2576 or threaded connector SC 65 to DIN 11851 Measurin...

Страница 20: ...ith integral junction box material 1 4301 Protection type IP 65 Temperature range Operating temperature for the detector 20 to 50 C 253 to 323 K Storage temperature 40 to 65 C 233 to 338 K Measuring p...

Страница 21: ...measuring path The responsibility of choosing the right lining lies with the operator The LB 379 measuring path is pressurized twice The leak test is carried out with 2 bar air To improve the detectab...

Страница 22: ...llowing explanations 1 Activity Radiation is emitted as a result of nuclear disintegration The higher the number of these nuclear transformations the higher the activity Unit of measure is the Becquer...

Страница 23: ...S 0 693 0 693 5 0 9 47 Determine the dose rate in a distance of 0 6 m using the following formula mrem Sv s a t k a D 846 0 46 8 47 2 0 1 0043 0 3700 2 2 A activity in MBq k radiation constant t time...

Страница 24: ...eater the longer one is exposed to radiation Therefore it is especially important when working with radioactive sources to prepare work carefully and complete it quickly This is especially true when t...

Страница 25: ...carried out under expert supervision If adequate know how as well as suitable instruments are available emergency measures may be taken immediately In this case proceed as follows Check the effectiven...

Страница 26: ...de of the photomultiplier Figure 8 Assembly of the scintillation counter Open the scintillation counter by removing the cover of the con nection box first and then the screws of the base The entire el...

Страница 27: ...damage to the dynode systems e g by excessive vibration cannot be identified by appearance If in doubt replace the multiplier The glass pane at the mating face to the photo multiplier must not show an...

Страница 28: ...lution 0 131 0 000048 0 00064 Hydrochloric acid HCl H2O 0 635 0 00028 0 0032 Sulfuric acid H2SO4 H2O 0 257 0 00013 0 00242 Nitric acid HNO3 H2O 0 117 0 000037 0 00062 Phosphoric acid H3PO4 H2O 0 235 0...

Страница 29: ...9300E 03 30 25 6 0000E 04 1 5720E 00 1 2150E 01 8 0000E 03 10 75 5 3800E 04 1 1960E 00 1 1160E 01 4 1450E 02 30 75 5 7600E 04 1 6610E 00 1 3330E 01 4 4380E 02 Sugar sol 10 20 0 0002377 0 621 0 05748...

Страница 30: ...97425 20 0 99823 50 0 98807 80 0 97183 21 0 99801 51 0 98761 81 0 97120 22 0 99779 52 0 98715 82 0 97057 23 0 99755 53 0 98668 83 0 96993 24 0 99731 54 0 98621 84 0 96929 25 0 99706 55 0 98673 85 0 9...

Страница 31: ...LB 379 31 9 Dimensional Drawings 9 1Measuring Path LB 379 with DIN Flange...

Страница 32: ...LB 379 32 9 2Measuring Path LB 379 with ASA Flange...

Страница 33: ...LB 379 33 9 3Measuring Path LB 379 with Threaded Connector...

Страница 34: ...LB 379 34 9 4Measuring Path LB 3602 03...

Страница 35: ...LB 379 35 10 ATEX Certificate...

Страница 36: ...LB 379 36...

Страница 37: ...LB 379 37...

Страница 38: ...LB 379 38...

Страница 39: ...LB 379 39...

Страница 40: ...LB 379 40...

Страница 41: ...LB 379 41...

Страница 42: ...cy instructions 25 Enclosed radioactive materials 12 M Mu metal shielding 26 P Photocathode 27 Photomultiplier 26 Pt100 18 R Radiation Protection Instructions 5 Radiation Protection Officer 13 Radioac...

Страница 43: ...LB 379 BERTHOLD TECHNOLOGIES GmbH Co KG Calmbacher Str 22 D 75323 Bad Wildbad Germany www Berthold com...

Отзывы: