LB 379
15
Figure 5: Installation on a horizontal pipeline with gas bubbles and debris
Extensions of the pipeline should be avoided. If they are unavoidable, they should always
be performed only on vertical lines.
Pipe extensions may be made at the measurement point only if
a continuous flow of product is ensured over the entire pipe cross section. Par-
ticularly with highly viscous products this will not always be the case. Usually,
the product flows only in the center. However, the measurement covers the entire
diameter of the product in the path or radiation. Therefore, the measurement
result is not representative.
no gas bubbles are present in the path of radiation.
suspension measurements are not carried out directly behind a pipe-bend, for
there the material will not be distributed homogeneously.
The distance from the bend must be the larger
the higher the flow rate
the bigger the difference between liquid density and solid density
d)
Measuring system installed outdoors have to be protected from rain and direct sun-
shine by a canopy.
Figure 6: Canopy roof for protection against sun and rain in outdoor installations
Gas bubbles
Debris
Содержание LB 3602
Страница 1: ...Measuring Path LB 379 and LB 3602 3603 Operating Manual 40437BA2 Rev No 00 12 2016...
Страница 2: ...LB 379 2...
Страница 4: ...LB 379 4...
Страница 31: ...LB 379 31 9 Dimensional Drawings 9 1Measuring Path LB 379 with DIN Flange...
Страница 32: ...LB 379 32 9 2Measuring Path LB 379 with ASA Flange...
Страница 33: ...LB 379 33 9 3Measuring Path LB 379 with Threaded Connector...
Страница 34: ...LB 379 34 9 4Measuring Path LB 3602 03...
Страница 35: ...LB 379 35 10 ATEX Certificate...
Страница 36: ...LB 379 36...
Страница 37: ...LB 379 37...
Страница 38: ...LB 379 38...
Страница 39: ...LB 379 39...
Страница 40: ...LB 379 40...
Страница 41: ...LB 379 41...
Страница 43: ...LB 379 BERTHOLD TECHNOLOGIES GmbH Co KG Calmbacher Str 22 D 75323 Bad Wildbad Germany www Berthold com...