troubleshooting
error
Possible cause
Measures taken by operators or
service personnel
No heating up
Power indicator lamp is OFF
No power supply
Check that the device is connected to the power
supply (power cable plugged in) or that the main
switch is turned on.
Rotary knob in OFF position
Turn the knob into one position
Main switch is OFF
Turn the main switch into one position
Inductiongerät defective
Contact your repair service supplier. Remove the
power plug from the power outlet.
Insufficient heating capacity
Power indicator lamp is
ON (lights)
Air cooling system is
disabled/blocked
Make sure that the air supply and export are not
obstructed/blocked.
Air filter is dirty.
Clean or replace filters.
Ambient temperature is too high
(the cooling system cannot keep
the cooker in normal operating
temperatures
*2
Make sure that no hot air is sucked in. Reduce the
ambient temperature. The temperature must not
exceed 40°C / 110 °F.
A phase is missing
Check the backups.
Inductiongerät defective
Contact your repair service supplier. Pull the
power plug.
No reaction to turning the
temperatureknob
Temperaturregler defective
Heating capacity stops and off
within minutes.
Fan works
Air cooling system is
Blocked/disturbed
Make sure that the air supply and export are not
blocked.
Fan dirty
Cleaning fans
Heating capacity stops and off
within minutes. Fan is not
working.
Fan or fan monitoring defective
Contact your repair service supplier. Pull the
power plug.
Heating capacity stops and
downs within minutes
(after longern, continuous
operating time)
Coil overheated,
Heating zone too hot.
Turn off the device, remove the pan and wait for
the heating zone to cool down.
No heating up
Triggering the
Safety temperature limiters
Should the safety temperature limiter trigger and
switch off the heating, the re-entry may only take
place after the cause of the failure has been
determined and its elimination!
After the device has cooled down, the red
entriege
lungs button can
be operated without
using force. Switching on again if the device is not
sufficiently cooled can
damage the safety
temperature limiter
s. Then, it is essential to
re-insert the
protective
cap
to restore the
water protection.
*2)The ventilation begins to work when the temperature of the cooling plate exceeds 45°C. At
cooling plate temperatures above 70°C, monitoring automatically reduces performance to keep
the power part under normal operating conditions. The inductiongerät continues normally with
reduced maximum power.
If the mains connection line of this device is damaged, it must be replaced by the
manufacturer or its customer service or a similarly qualified person to avoid hazards.
Содержание BGI40
Страница 19: ...side 18 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Страница 22: ...side 21 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 manager...
Страница 23: ...side 22 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 List of spare parts BIPS Generator...
Страница 24: ...side 23 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Страница 25: ...side 24 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 BIPDS Generators...
Страница 26: ...side 25 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...