If other built-in devices are installed near the induction or are located nearby, which are
electronically controlled, please ask the manufacturer if interference caused by the induction
is possible.
Additional installation requirements for the installation model
-
The intake air must be channelled and fed directly to the fans via the supplied filter. The
suction cross-section should be at least 200 cm2.
-
The maximum intake air must never exceed the temperature of 35°C directly in front of the
fans.
-
Do not build a thermal short circuit. The exhaust air must not be sucked back in, otherwise
the device will become hotter and hotter.
-
The installation must be checked for practicality. For this purpose, the maximum cooling
plate temperature must be determined. The measured plate under the induction coil in the
middle of the transistor module (black large block) is measured at the cooling plate base
plate below the induction coil. The temperature must not exceed 50°C in continuous
operation of at least 2 hours and 20°C ambient temperature.
-
Shield the potentiometer line at lengths above 60 cm and connect it to terminal S only on
the induction module.
-
The generator supply must be generally shielded and contacted cleanly on both sides.
-
Provide the mains disconnector in such a way that a maximum of 5 times per day is switched
on and off.
Attention points for remote coil (coil - generator separated)
-
With shock connector and 6 mm2 Radox strand (155°C) extend the coil connections and
solder with.
-
Extend sensor cable with 2 x 0.5 mm2 oil flex cable.
-
Sensor and display cables must be laid separately from coil cables and all other cables and,
if possible, placed in a steel channel, as the interference emission is very high.
-
The cooling system is designed to cool the coil (see point 5). This is no longer the case with
a detached coil. The coil should therefore be ventilated separately (optionally available), so
that the temperature of the ferrite rods does not exceed 140°C in continuous operation
(check by means of temperature measurements).
-
No sheets may be mounted under the coil which are less than 6 cm apart, except for
aluminium, where 2.5 cm is considered the minimum distance.
-
The module complies with EMC standards and electrical safety requirements. If the coil is
removed, some tests must still be repeated. e.B. temperature tests, EMC test, electrical
safety. The execution of the inspections is the responsibility of the user and should be
confirmed by an accredited inspection body.
Содержание BGI40
Страница 19: ...side 18 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Страница 22: ...side 21 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 manager...
Страница 23: ...side 22 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 List of spare parts BIPS Generator...
Страница 24: ...side 23 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...
Страница 25: ...side 24 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014 BIPDS Generators...
Страница 26: ...side 25 from 34 08 11 2014 Ver 2 9 Berner cooking systems 2014...