![Berker 8534 51 series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/berker/8534-51-series/8534-51-series_operating-instructions-manual_2737384006.webp)
Radio motion detector comfort 1.1 m/2.2 m quicklink
Page 6/18
6W-5827
09-2012
Activating/deactivating presence simulation
During operation, the motion detector counts the motion detections in one full hour and saves
the result. With active presence simulation at the beginning of the hour with the most detections
saved, the light will be switched on for the duration of the delay time, even no motion is detec
-
ted.
During the presence simulation presence detection, extension unit and radio commands will
continue to be executed normally.
Keep the button pressed for more than 20 seconds, until the status LED is slowly flashing
red (Fig. 3).
The presence simulation is active. During this time the status LED lights orange. The moti
-
on detector switches the lighting on at the saved time.
Briefly press the button.
The presence simulation will be disabled, the motion detector returns
to
Auto
mode.
Setting the load
If the dimming and switching performance of loads is unsatisfactory after start-up, especially
when circuited to energy-saving lamps and 230 V LED lamps, a load setting must be carried out
for universal switch inserts or universal touch dimmers.
Switch off load.
Keep the button pressed for more than 25 seconds, until the status LED is slowly flashing
orange.
The connected load blinks once. The device is in selection mode.
If there is no further operation within the next 10 seconds, the insert swiches to switching/
dimming operation.
Briefly press the button repeatedly to activate the desired setting mode (Table 3).
The load setting is executed.
Briefly
press the
button
Setting mode
Confirmation of the
load setting
Notes
1 x
Load fine-setting
Load blinks 1 x after
approx. 30 s and changes
to switching/dimming ope
-
ration
Not suitable for ohmic loads (e.g. incandescent,
HV halogen lamps); use factory load setting.
If the load fine-setting does not bring any impro-
vement for energy-saving lamps or 230 V LED
lamps, select the energy-saving lamp fine-setting
or 230 V LED lamp universal setting.
2 x
Factory load setting
Load blinks 2 x after
approx. 6 s and changes
to switching/dimming ope
-
ration
3 x
Energy-saving lamp
fine-setting in phase
cut-on
Load blinks 3 x after
approx. 30 s and changes
to switching/dimming ope
-
ration
Energy-saving lamps are switched ON at a
brightness level of at least 50% brightness in
order to ensure an ignition process.
4 x
230 V LED lamp
universal setting in
phase cut-off
Load blinks 4 x after
approx. 5 s and changes
to switching/dimming ope
-
ration
The universal setting contains standard values
which enable the operation of typical dimmable
230 V LED lamps.
For all setting modes Load blinks 5 x
The selected setting mode is not supported by
the insert.
Table 3: Load setting mode