![Berker 8534 51 series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/berker/8534-51-series/8534-51-series_operating-instructions-manual_2737384017.webp)
Radio motion detector comfort 1.1 m/2.2 m quicklink
Page 17/18
6W-5827
09-2012
To accept the selected switch-on time, keep pressed the
fct
button for longer than 2 se
-
conds.
Finish configuration:
Short press on
cfg
button on the transmitter.
Resetting the radio motion detector to factory settings
The device is not in configuration mode.
Keep the
cfg
button pressed for more than 10 seconds until the
cfg
LED changes from a
red lighting to blinking.
Release the
cfg
button.
The
cfg
LED blinks red rapidly. The device re-initialises itself. In the meantime the
cfg
LED
lights up in red colour. After that the LED goes out and blinks 5 x to indicate the compatibili
-
ty. The reset is made. The process lasts about 20 s.
This process deletes the complete configuration of the radio motion detector. Settings of
the insert (switch-on brightness-level, load setting) are not reset.
6. Appendix
6.1 Technical data
Connection
Mounting on suitable inserts
Power supply
via inserts
Response brightness
approx. 5 ... 1000 lux (∞)
Sensitivity
approx. 10 ... 100 %
Detection angle
approx. 90 ... 180°
Detection area (1.1 m)
approx. 12 x 16 m
Detection area (2.2 m)
approx. 8 x 12 m
Radio frequency
868 MHz
Radio protocol
KNX radio
quicklink logic functions
max. 20 transmitters/receivers
Receiver category
2
Transmitter duty cycle
< 1%
Degree of protection
IP 20
Relative humidity
0 ... 65 % (no condensation)
Ambient temperature
-5 … +45 °C
Storage/transport temperature
-20 … +60 °C
Mounting orientation
Interface between application and power module at top
6.2 Accessories
Relay insert
8512 12 0x
Universal switch insert 1-gang
8512 11 0x
Touch dimmer (R, L)
8542 11 0x
Universal touch dimmer 1gang
8542 12 0x
Power supply for radio application module
8502 01 0x