background image

Radio motion detector comfort 1.1 m/2.2 m quicklink

Page 1/18

6W-5827

09-2012

Radio motion detector comfort 1.1 m/2.2 m quicklink

Order number 8534 51 ..

Operating instructions 

1.  Safety instructions

Electrical equipment may only be installed and assembled by a qualified electrician in ac-

cordance with the relevant installation standards, regulations, directives and safety and 

accident prevention directives of the country.
Failure to comply with these instructions may result in damage to the device, fire or other 

hazards.
The radio transmission is not suitable for safety or alarm applications.
Due to its detection behaviour the device is not suitable for use in burglary detection or 

alarm systems.
These instructions are an integral component of the product and must be retained by the 

end user.

2.  Design and layout of the device

(3)

(4)

(5)

(2)

(1)

(6)

Figure 1: Design and layout of the device

(1)  Insert (see "Accessories", not in scope of delivery) 
(2)  Frame (not within scope of delivery)
(3)  Application module
(4)  Motion detector design cover
(5)  Screw for dismantling protection (not for design lines R.1/R.3) 
(6)  Interface between insert/application module

Содержание 8534 51 series

Страница 1: ...y result in damage to the device fire or other hazards The radio transmission is not suitable for safety or alarm applications Due to its detection behaviour the device is not suitable for use in burg...

Страница 2: ...nsitivity Adjustable detection angle for adaptation of the detection area Additional adjustment of the response brightness via Teach In function Party function Presence simulation Optional extension u...

Страница 3: ...oaded from memory During this period local operation via the button or extension unit can be used 4 Operation Operating concept 8 7 Fig 2 Operating and display elements 7 Button 8 Status LED Operation...

Страница 4: ...ent OFF Table 1 Display of operating modes Disabling enabling operating mode selection via button Keep the button pressed for more than 15 seconds until the status LED is flashing green Fig 3 Selectio...

Страница 5: ...tches the lighting on for 2 hours During this time no extension unit or ra dio commands are executed Keep the button pressed for more than 5 seconds until the status LED is flashing red Fig 3 The ligh...

Страница 6: ...range The connected load blinks once The device is in selection mode If there is no further operation within the next 10 seconds the insert swiches to switching dimming operation Briefly press the but...

Страница 7: ...ve the motion orientation a distinction is made between direct approach and trans verse motion Motions transverse to the motion detector can be detected better than moti ons toward the motion detector...

Страница 8: ...le must be reset to factory settings If available fix dismantling protection with screw 5 After radio configuration and start up click the design cover 4 into place on the applicati on module 3 5 2 St...

Страница 9: ...rformance Test mode must be used to test the detection performance In test mode the motion detector works independent of brightness Each detection switches the lighting and the status LED on for 3 sec...

Страница 10: ...sed The following can be configured The local operation of the load connected to the insert Radio commands to control other receivers Functions which are executed when the radio commands are received...

Страница 11: ...N for the set delay time The brightness evaluation only takes place on the ma ster the slave only detects motion Can only be configured between radio motion detec tors Delete No function Assignment to...

Страница 12: ...e motion detec tor indicates the currently configured function T 150 90 45 45 90 fct cfg Select function at receiver Repeated short press on fct button on the motion detector until the desired functio...

Страница 13: ...pply for radio application modules then it can only be configured as a transmitting extension unit slave see Executing a master slave configuration Down below there is an illustration of the configura...

Страница 14: ...essful saving the fct LED signals the saved function A quick blinking of the cfg LED indicates a combi nation that is not possible or an error Finish configuration Short press on cfg button on the rad...

Страница 15: ...d master light up in red colour T 150 90 45 45 90 fct cfg T 150 90 45 45 90 fct cfg All receivers within radio range also indicate the confi guration mode Select function at receiver Short press on cf...

Страница 16: ...above on each receiver to be integrated and confirm function on the receiver Finish configuration Short press on cfg button on the transmitter Setting of switch on time for function timer In order to...

Страница 17: ...nfiguration of the radio motion detector Settings of the insert switch on brightness level load setting are not reset 6 Appendix 6 1 Technical data Connection Mounting on suitable inserts Power supply...

Страница 18: ...erest of technical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point of sale or ship the device postage free...

Отзывы: