RACK MOUNT
Installation
44
OptiPac 2652MD User's Manual
B
s
CAUTION
The following steps require two people to install the unit in a cabinet.
The rack requires 5.25 inches of vertical clearance. The optional 1.75”
x 19.0” panel increases the vertical clearance to 7.0”.
3. Insert the shelf with the Bering drive into the cabinet and hold it in place.
4. Insert the four 10-32x3/4 screws from the front through the holes in
the cabinet. Screw the 10-32 nuts on the screws from the rear of the
cabinet and tighten.
5. If you have the optional 1.75” x 19.0” panel, insert it above the rack
mount assembly and attach it to the rack with two 10-32x3/4 screws.
Figure B-2: Installing the rack mount in the chassis
10-32x5/16, 4 places