4
1 GENERAL INFORMATION
1 1 General Safety Information
b
After removing the packaging, check the condition
and completeness of the supply. If there are any
problems, contact the company
B
that sold the
equipment.
b
This product must be installed by a legally qualified
heating engineer. On completion of the installation,
the installer must issue the owner with a declaration
of conformity confirming that the installation has been
completed to the highest standards in compliance
with the instructions provided by
B
in this instruc-
tion manual, and that it conforms to all applicable
laws and standards.
b
This product must only be used for the purpose
for which it is designed and made, as specified by
B
.
B
declines all responsibility, contractual or
other, for damage to property or injury to persons or
animals caused by improper installation, adjustment,
maintenance or use.
b
In the event of a water leak, disconnect the thermal
module from the main power supply, shut off the water
supply and promptly notify the Technical Assistance
Centre
B
or professionally qualified personnel.
b
Periodically check that operating pressure in the wa-
ter circuit is over 1 bar but below the maximum limit
specified for the boiler. If this is not the case, contact
Technical Assistance Centre
B
or a professional-
ly qualified heating engineer.
b
The following operations shall be necessary if the
thermal module is not used for a long period of time:
- Switch the boiler OFF at the control panel
- Turn the main system switch "off"
- Close the fuel cock and heating circuit water cock
- Drain the central heating circuit if there is any risk of
freezing.
b
Maintenance must be performed on the thermal mod-
ule at least once a year.
b
This manual is an integral part of the appliance and
must therefore be kept with care and must ALWAYS
accompany the thermal module, even when it is
passed on to another owner or user or transferred to
another installation. If it is lost or damaged, please
contact your local Technical Assistance Centre
B
for a new copy.
b
This manual must be read carefully so as to ensure
the correct and safe installation, operation and main-
tenance of the appliance. The Owner must be ade-
quately informed and trained on how to operate the
appliance. Make sure that he/she is familiar with all
the information required for safe system operation.
b
The thermal module, before being connected to the
hydraulic system, the gas network, and the electrical
system, may be exposed to temperatures ranging
from 4°C to 40°C. After it can activate the Frost Pro-
tection function, it can be exposed to temperatures
ranging from -20°C to 40° C
b
Regularly check that the condensate drain is free
from obstruction.
b
We recommend cleaning inside the exchanger once
a year, extracting jet and burner and removing any
installation debris by suction. This operation will be
done by personnel from the Technical Assistance
Centre only.
1 2 Precautions
The operation of any appliance that uses fuel, electrical
power and water demands that a number of fundamental
safety precautions be respected:
a
Do not allow children or infirm persons to operate the
system unsupervised.
a
It is forbidden to use electrical devices or equipment,
such as switches, appliances, etc. if there is a smell
of gas or un-burnt products. If so:
- Ventilate the room, opening doors and windows
- Close the fuel shut-off cock
- Report the fault immediately to the
B
's Technical
Assistance Centre or a professionally qualified heat-
ing engineer.
a
Do not touch the boiler while barefoot or wet.
a
Any technical or cleaning activity is forbidden before
disconnecting the appliance from the main power
supply by switching the system's master switch and
the appliance's main switch to the "OFF" position.
a
Do not tamper with or adjust the safety or control de-
vices without prior authorisation and instructions from
the manufacturer.
a
Do not plug or block the condensate drain outlet.
a
Never pull, disconnect, or twist the electrical cables
coming from the appliance even if it is disconnected
from the mains electricity supply.
a
Do not obstruct or restrict the vents in the room where
the boiler is installed. Adequate ventilation is essen-
tial for correct combustion.
a
Do not expose the appliance to weather elements
(without using the dedicated accessory). It has been
designed for indoor use.
a
Do not switch off the appliance if the outdoor temper-
ature may drop to below ZERO (frost hazard).
a
Do not leave flammable containers and substances
in the room where the device is installed.
a
Do not dispose of packaging material into the envi-
ronment, or leave it within the reach of children, since
it can become a potential hazard. Dispose of packag-
ing material in compliance with applicable legislation.
a
Do not activate the thermal module without water.
a
Individuals without specific qualifications and skills
are not allowed not remove the thermal module's
casing.
Содержание POWER MAX 100
Страница 58: ...SYSTEM MANAGER 58 ...
Страница 59: ...SYSTEM MANAGER 59 ...