![Beretta POWER MAX 100 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/beretta/power-max-100/power-max-100_installation-and-operation-manual_2736679050.webp)
50
Removing the fan and the burner models POWER MAX
50 P DEP - POWER MAX 50 P
- Remove the locking screws and the panel's front side
- Remove cables (1) and (2) for the fan (3)
- Remove the air pipe from the fan if the thermal mod-
ule is type C (C type configuration non standard but
obtained with specific accessory)
- Unscrew the swivel nut (4) and disconnect the gas
pipe
- Use a socket wrench to unscrew the four nuts (5) fix-
ing the fan (3) to the flange (6)
1
3
6
2
4
5
5
- Take the fan (3) and the gasket (7) out
- Unscrew the four nuts (8) fixing the flange (6) to the
top closing (9)
- Remove the gasket (10) and the burner (11).
6
9
8
8
10
11
3
7
- Replace the gaskets (7-10) with the new ones.
Once the maintenance operations are complete, refit the
components working in the opposite direction of what was
described.
b
Check that the gas connection is leak proof.
Disassembling of the fan and burners models POWER
MAX 65 P - POWER MAX 80 P
- Remove the locking screws and the panel's front side
- Remove cables (1) and (2) for the fan (3)
- Remove the air pipe from the fan if the thermal mod-
ule is type C (C type configuration non standard but
obtained with specific accessory)
- Unscrew the swivel nut (4) and disconnect the gas
pipe
- Unscrew the four screws with a pipe wrench (5) fixing
the fan (3) to the flange (6)
1
4
5
5
3
2
6
- Take the fan (3) and the gasket (7) out
- Unscrew the 4 screws (8) that fix the flange (6) to the
lower flange (9)
- Remove the gasket (10) and the burner (11).
3
8
7
6
11
8
9
10
- Replace the gaskets (7-10) with the new ones.
Once the maintenance operations are complete, refit the
components working in the opposite direction of what was
described.
b
Check that the gas connection is leak proof.
Содержание POWER MAX 100
Страница 58: ...SYSTEM MANAGER 58 ...
Страница 59: ...SYSTEM MANAGER 59 ...